1 * 1 7
LOBBY PARTITION
Enter the "common lobby" partition (1-8)
1 * 1 8
AFFECTS LOBBY
Enter 1 if this partition affects the common lobby;
enter 0 if it does not
1 * 1 9
ARMS LOBBY
Enter 1 if arming this partition attempts to arm lobby;
enter 0 if it does not
1 * 2 0
EXIT ERROR LOGIC
1=Enable (E/E and interior zones will be bypassed if faulted
after exit delay); 0=Disable
1 * 2 1
EXIT DELAY RESET
0=No; 1=Resets Exit Delay to 60 seconds after
zone is closed.
FIELDS 1*22-1*25: Allow four sets of two zones each to be
linked so that both must fault within a five minute period to
cause an alarm.
1 * 2 2
CROSS-ZONING PAIR ONE
1 * 2 3
CROSS-ZONING PAIR TWO
1 * 2 4
CROSS-ZONING PAIR THREE
1 * 2 5
CROSS-ZONING PAIR FOUR
1 * 2 8
RF TX LOW BATTERY SOUND
1=immediate; 0=when disarmed; Must be "1" for UL
1 * 2 9
RF TX LOW BATTERY REPORT ENABLE
1=enable; 0=disable
Must be "1" for UL
1 * 3 0
RF RCVR CHECK-IN INTERVAL
02-15 times 2 hours; 00 disables supervision
Max. "6" (12 hr) for UL
1 * 3 1
RF TRANSMITTER CHECK-IN INTERVAL[12]
02-15 times 2 hours; 00 disables transmitter supervision
Max. "6" (12 hr) for UL
1 * 3 2
RF RECEIVER TYPE
1=4281 ( must have correct revision level); 2=5881
1 * 3 3
TOUCH-TONE W/ROTARY BACKUP
1=enable; 0=disable
1 * 3 4
COMM. SPLIT REPORT SELECTION
0=no; 1=alarms primary, others secondary;
2=open/close, test secondary, others primary; See *51 for
comments.
ALARM REPORT CODE & ID DIGITS FOR ZONES
65-80 & SUPV. & RESTORE CODES
1*35 CODE
1*36 ID
1*37 CODE
65
|
|
73
66
|
|
74
67
|
|
75
68
|
|
76
69
|
|
77
70
|
|
78
71
|
|
79
72
|
|
80
– 10 –
[0]
[0]
[0]
[0]
[0]
|
|
|
|
|
|
|
|
[0]
[0]
[06]
[0]
[0]
[0]
[codes default to zero]
1*38 ID
1*39
|
|
|
Alarm Rst.
|
|
|
Trouble
|
|
|
Trble Rst.
|
|
|
Bypass
|
|
|
Byps Rstt
|
|
|
|
|
|
NON-ALARM DIALER CODES
Armed STAY
Time/Date set or event log reset
Event log 50% & 90% full
Event log overflow
Exit Error (Zone)
Exit Error (User)
Recent Close
1 * 4 2
CALL WAITING DEFEAT
1=Yes; 0=No
1 * 4 3
PERM. KEYPAD BACKLIGHT
1=enable; 0=disable When disabled, display lights when any
key is pressed, and turns off after period of keypad inactivity.
1 * 4 4
WIRELESS KEYPAD
TAMPER DETECT ENABLE
1 * 4 5
EXIT DELAY SOUNDING
1=enable; 0=disable Produces quick beeping during exit
delay if enabled.
1 * 4 6
AUXILIARY OUTPUT MODE
0=ground start; 1=open/close trigger; 2=keypad sounding;
3=AAV trigger
1 * 4 7
CHIME ON EXTERNAL SIREN
1=enable; 0=disable
1 * 4 8
WIRELESS KEYPAD ASSIGNMENT
0=disable; enter partition in which RF keypad used, 1-8.
1 * 4 9
SUPPRESS TX SUPERVISION SOUND
1=disable; 0=enable. Must be "0" for UL.
|
1 * 5 2
SEND CANCEL IF ALARM + OFF
1=no restriction; 0=within Bell Timeout period only
1 * 5 3
DOWNLOAD CALLBACK
|
1=callback not required; 0=callback required; Must be "0" forUL.
1 * 5 7
5800 RF BUTTON GLOBAL ARM
Enter "1" to have the system arm/disarm following the button
user's global arm settings. Enter "0" if the button is not to be
used to global arm the system.
1 * 5 8
5800 RF BUTTON FORCE ARM
Enter "1" to enable. If a zone is faulted after pressing button,
keypad will beep once. User should press button again within
4 sec. to force arm. Enter "0" to disable.
Must be disabled for UL Listed installations.
1 * 6 0
ZONE 5 AUDIO ALARM VERIFICATION
Enter 1 if 2-way audio (AAV) is being used; Enter 0 if it
is not.
1 * 7 0
EVENT LOG TYPES
1=enable logging; 0=disable Alrm
1 * 7 1
12/24 HOUR TIME STAMP FORMAT
0=12 hour; 1=24 hour
1 * 7 2
EVENT LOG PRINTER ON-LINE
0=disable; 1=enable
1 * 7 3
PRINTER BAUD RATE
1 * 7 4
RELAY TIMEOUT XX MINUTES
Enter the relay timeout, 0-127 in multiples of 2 minutes, desired
for #80 Menu Mode time driven event relay command numbers
"04/09" and #93 Menu Mode Relay Programming output
command "56".
( Armed Stay, Time Set & Event Logging)
1*40
1*41
First Digit
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1=enable; 0=disable
Chck
1=300; 0=1200
[000]
Second Digit
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[1]
[0]
[0]
[0]
[0]
[0]
Byps
O/C Systm
[0]
[0]
[0]
|
|