*43
DIAL TONE DETECTION
1=wait for true dial tone; 0=pause, then dial
* 4 4
RING DETECTION COUNT
01-14; 15=answering machine; 00=no detection
* 4 5
PRIMARY FORMAT
0=Low Speed; 1=Contact ID; 2=Ademco High Speed;
3=Ademco Express
* 4 6
LOW SPEED FORMAT (Primary)
0=Ademco Low Speed; 1=Sescoa/Radionics
* 4 7
SECONDARY FORMAT
0=Low Speed; 1=Contact ID; 2=Ademco High Speed;
3=Ademco Express
* 4 8
LOW SPEED FORMAT (Sec.)
0=Ademco Low Speed; 1=Sescoa/Radionics
* 4 9
CHECKSUM VERIFICATION
1=yes; 0=no
* 5 0
SESCOA/RADIONICS SELECT
1=Sescoa; 0=Radionics
* 5 1
DUAL REPORTING
1=yes; 0=no If used with Spilt Reporting "1" option (1*34),
alarms go to both primary & secondary numbers, while all other
reports go to secondary only. If used with Split Reporting "2"
option, alarms go to both, open/close and test messages go to
secondary only, while all other reports go to primary.
* 5 2
STANDARD/EXPANDED REPORT (PRIMARY)
Alarm
Rstr
Bypass Trbl
0=standard; 1=expanded; Note: Expanded overrides 4+2 format
* 5 3
STANDARD/EXPANDED REPORT (SECONDARY)
Alarm
Rstr
Bypass Trbl
0=standard; 1=expanded; Note: Expanded overrides 4+2 format
ALARM REPORT CODE & ID DIGITS FOR ZONES 1-32 &
SUPV. & RESTORE CODES
*54
*55
*56
CODE
I D
1
|
|
9
2
|
|
10
3
|
|
11
4
|
|
12
5
|
|
13
6
|
|
14
7
|
|
15
8
|
|
16
*59
*60
*61
CODE
ID
17
|
|
25
18
|
|
26
19
|
|
27
20
|
|
28
21
|
|
29
22
|
|
30
23
|
|
31
24
|
|
32
– 8 –
[1]
[00]
[0]
[0]
[0]
[0]
[0] [0]
PrimScndry
[0]
Opn/Cls Low Bat
[0]
Opn/Cls Low Bat
[All codes default to 00]
*57
* 5 8
CODE
ID
|
|
|
Alarm Rst.
|
|
|
Trouble
|
|
|
Trble Rst.
|
|
|
Bypass
|
|
|
Bypss Rst.
|
|
|
|
|
|
*62
*63
CODE
ID
|
|
|
Alarm Rst.
|
|
|
Trouble
|
|
|
Trble Rst.
|
|
|
Bypass
|
|
|
Bypss Rst.
|
|
|
|
|
|
ALARM REPORT CODE & ID DIGITS FOR ZONES 33-64 &
SUPV. & RESTORE CODES
*64
*65
CODE
|
33
|
34
|
35
|
36
|
37
|
38
|
39
|
40
|
*69
*70
CODE
49
|
50
|
[0]
51
|
[0]
52
|
53
|
54
|
55
|
56
|
ALARM REPORT CODE & ID DIGITS FOR ZONES 81-87, RF
RCVRs & PANICS, & THEIR SUPV. & RESTORE CODES
*74
*75
CODE
81
|
82
|
83
|
84
|
85
|
86
|
87
|
88
|
*78
|
Alarm Rst.
|
Trouble
|
Trble Rst.
|
Bypass
|
Bypss Rst.
ZONE TYPE RESTORE ENABLES
1=enable; [0=disable]
*79
FOR ZONE TYPES 1-8
1
2
3
[All codes default to 00]
*66
*67
ID
CODE
ID
|
41
|
|
|
42
|
|
|
43
|
|
|
44
|
|
|
45
|
|
|
46
|
|
|
47
|
|
|
48
|
|
*71
*72
ID
CODE
ID
|
57
|
|
|
58
|
|
|
59
|
|
|
60
|
|
|
61
|
|
|
62
|
|
|
63
|
|
|
64
|
|
*
76
*77
I D
CODE
|
89
|
|
|
90
|
|
|
91
|
|
|
|
|
|
97
|
|
|
95
|
|
|
96
|
|
|
99
|
|
NOTES: 97= Poll Loop Short; 88 & 90 = RCVR not
receiving transmitter signals. 89 & 91 = RCVR not
responding, bad conn. to panel. 87 = Voice Module
supervision.
*80
4
5
6
7
8
*68
|
Alarm Rst.
|
Trouble
|
Trble Rst.
|
Bypass
|
Bypss Rst.
*73
|
Alarm Rst.
|
Trouble
|
Trble Rst.
|
Bypass
|
Bypss Rst.
ID
[All codes default=00]
Duress
Poll loop short
(panic key 1+*)
( panic key 3+#)
( panic key * + #)
FOR TYPES 9/10
9
10