ADEMCO VISTA-50P Quick Start Manual page 3

Partitioned security system with scheduling, step-by-step programming procedure, single and multiple partition programming forms system worksheets
Hide thumbs Also See for VISTA-50P:
Table of Contents

Advertisement

SUMMARY OF PROGRAMMING COMMANDS....................................................................................... 2
RECOMMENDED PROGRAMMING PROCEDURE................................................................................. 3
PROGRAM FIELD CATEGORIES ............................................................................................................. 5
VISTA-50P/PUL SINGLE PARTITION PROGRAMMING FORM.............................................................. 6
VISTA-50P/PUL MULTIPLE-PARTITION PROGRAMMING FORM ....................................................... 11
PROGRAMMING WITH #93 MENU MODE............................................................................................. 17
SYSTEM LAYOUT WORKSHEETS ........................................................................................................ 18
The purpose of this document is to provide a quick and easy way to program your entire system. A
recommended programming procedure is included, followed by a list of program fields with the
corresponding program group they belong to (system-wide, partition-specific, scheduling, etc.). Two
program forms are included, one for a single-partition system, and the other for a multiple partition system.
If you are setting up a single-partition system, the partition-specific fields become system-wide fields.
Following the program forms are system layout worksheets. We recommend that you use these sheets
to plan your system before programming is performed. If you need further information about specific
programming options, see the VISTA-50P/VISTA-50PUL INSTALLATION INSTRUCTIONS.
Two programming forms are provided: Single Partition Form and Multiple-Partition Form
Make sure that one two-line alpha keypad is connected to the control and is set to device
address "00."
Single Partition System
The system default is for a single partition system.
PARTITION PROGRAMMING FORM beginning on page 7 when programming for single
partition usage. Follow the steps outlined on page 4 of this document for proper programming
procedure.
Multiple-Partition System
You must enter the number of partitions you are using in data field 2*00 to set the system for
multiple partitions. Use the VISTA-50P/PUL MULTIPLE-PARTITION PROGRAMMING FORM
beginning on page 13 when programming the system for multiple partitions. Follow the steps
outlined on page 4 of this document for proper programming procedure.
• To enter program mode, enter installer code + [8] + [0] + [0]
• To set standard defaults, press *97
• To set communication defaults, press *94 + one of the following: *80=low speed; *81=Ademco
Express; *82=Ademco High Speed; *83=Ademco's Contact ID
• To change to next page of program fields, press *94
• To return to previous set of fields, press *99
• To erase account & phone number field entries, press [*] + field number + [*]
• To assign zone descriptors, press #93 + follow menu prompts
• To add custom words, press #93 + follow menu prompts
• To enter Installer's Message, press #93 + follow menu prompts
• To exit program mode, press *99 OR *98: *99 allows re-access to programming mode by installer code.
*98 prevents re-access to programming mode by installer code.
Standard default (*97) values are shown in brackets [ ], otherwise default = 0.