Some fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section for
programming these fields. Standard default (*97) values are shown in brackets [ ], otherwise default = 0.
Fields bordered by dotted line can be programmed using the #93 Menu mode.
* 0 0
INSTALLER CODE
Enter 4 digits, 0-9 [4140]
ASSIGN RESPONSE TYPE FOR ZONES 1-27, 95-99
(Enter 00-10) see fields 1*01-1*09 for response types for zones 28-87.
*02
*03
1
|
9
|
17
2
|
10
|
18
3
|
11
|
19
4
|
12
|
20
5
|
13
|
21
6
|
14
|
22
7
|
15
|
23
8
|
16
|
24
RESPONSE TYPES: 00 = Disabled zone; 01 = Entry/Exit #1;
02 = Entry/Exit #2; 03 = Perimeter; 04 = Interior Follower;
05 = Day/Night; 06 = 24 hour Silent Alarm; 07 = 24 hour Audible Alarm;
08 = 24 hour Auxiliary; 09 = Fire; 10 = Interior, Delay; 20 = arm stay;
21 = arm away; 22 = disarm; 23= no alarm response
Refer to Partition-Specific section of this
form for programming shaded fields.
* 0 9
ENTRY DELAY #1
* 1 0
EXIT DELAY #1
* 1 1
ENTRY DELAY #2
* 1 2
EXIT DELAY #2
* 1 3
ALARM SOUNDER DURATION
* 1 4
ZONE 9 RESPONSE TIME
1=fast; 0= normal; "0" for UL.
* 1 5
KEYSWITCH ASSIGNMENT
Enter partition in which keyswitch used, 1-8; 0=disable
*16
CONFIRMATION OF ARMING DING
* 1 7
AC LOSS KEYPAD SOUNDING
1=yes; 0=no
* 1 8 UL
AC LOSS SIREN
1=yes; 0=no
* 1 9
RANDOMIZE AC LOSS REPORT
1=randomize 10-40 min.; 0=no
* 2 0
VOICE MODULE PHONE CODE [00]
Enter 01-09 for 1st digit; 11 (for *) or 12 (for #) for 2nd digit.
To disable voice module, enter 1st digit = 00 & 2nd digit = 11
Must be disabled for UL Listed installations.
* 2 1
PREVENT FIRE TIME-OUT
1=no timeout; 0=fire timeout
* 2 2
KEYPAD PANIC ENABLES
* 2 3
MULTIPLE ALARMS
* 2 4
IGNORE EXPANSION ZONE TAMPER
1=yes; 0=enable for RF and RPMs
* 2 5
BURG.TRIGGER FOR RESPONSE TYPE 8
1=enable; 0=disable
* 2 6
INTELLIGENT TEST REPORTING
Set "0" for UL 1=yes, (no report sent if any other report
was recently sent); 0=no
* 2 7
TEST REPORT INTERVAL
Enter interval in hours, 001-999; 000=no report ; Max. 024
for UL.
VISTA 50P/VISTA 50-PUL
MULTIPLE PARTITION PROGRAMMING FORM
|
*04
*05
|
25
|
|
26
|
|
27
|
|
0 | 0
|
97
|
polling loop short
|
95
|
(1+
panic)
|
96
|
(3+ # panic)
|
99
|
( + # panic)

Partition-Specific

Partition-Specific
Partition-Specific
Partition-Specific
Partition-Specific
[0]
[0]
Partition-Specific
[0]
[0]
[0]
|
[0]
Partition-Specific
Partition-Specific
[1]
[0]
[024]
* 2 8
POWER UP IN PREVIOUS STATE
|
|
1=yes; 0=no; "1" for UL.
*29
QUICK ARM
* 3 0
TOUCH-TONE OR ROTARY DIAL
1=TouchTone; 0=rotary
* 3 1
PABX ACCESS CODE
00-09; B-F (11-15)
* 3 2
PRIM. SUBS. ACCT #
* 3 3
PRIMARY PHONE NUMBER
Enter 0-9 for each digit; enter #11 for *, #12 for #, and #13 for
2 sec. pause
* 3 4
SECONDARY PHONE NUMBER
Enter 0-9 for each digit; enter #11 for *, #12 for #, and #13 for
2 sec. pause
* 3 5
DOWNLOAD PHONE No.
Enter 0-9 for each digit; enter #11 for *, #12 for #, and #13 for
2 sec. pause
* 3 6
DOWNLOAD ID No.
|
|
Enter 00-09; A-F (10-15) [15 15 15 15 15 15 15 15]
* 3 7
DOWNLOAD COMMAND ENABLES
Dialer
System
Download
Shutdwn Shutdwn
Program
See field 1*53 for Callback disable option; [1=enable]; 0=disable; For UL
installations, all options must be disabled.
* 3 8
PREVENT ZONE XX BYPASS
* 3 9
OPEN/CLOSE REPORT
FOR INSTALLER
* 4 0
OPEN/CLOSE REPORT FOR KEYSWITCH
1=enable; 0=disable
|
* 4 1
NORMALLY CLOSED or EOLR (Zones 2-8)
1=N.C.loops; 0=EOLR supervision; Must be "0" for UL.
* 4 2
DIAL TONE PAUSE
0=5 seconds; 1=11 seconds; 2=30 seconds; Must be "0" for UL.
*43
DIAL TONE DETECTION
1=wait for true dial tone; 0=pause, then dial
* 4 4
RING DETECTION COUNT
[0]
01-14; 15=answering machine; 00=no detection
* 4 5
PRIMARY FORMAT
0=Low Speed; 1=Contact ID; 2=Ademco High Speed;
3=Ademco Express
* 4 6
LOW SPEED FORMAT (Primary)
0=Ademco Low Speed; 1=Sescoa/Radionics
* 4 7
SECONDARY FORMAT
|
|
0=Low Speed; 1=Contact ID; 2=Ademco High Speed;
3=Ademco Express
|
|
|
|
|
0
Not
Remote Remote Remote Upload
Used Bypass Disarm
Arm
[1]
Partition-Specific
[0]
|
|
Partition-Specific
|
|
|
Program
Partition-Specific
Partition-Specific
[0]
[1]
[0]
[1]
[00]
|
[0]
[0]
[0]