Partition-Specific - ADEMCO VISTA-50P Quick Start Manual

Partitioned security system with scheduling, step-by-step programming procedure, single and multiple partition programming forms system worksheets
Hide thumbs Also See for VISTA-50P:
Table of Contents

Advertisement

* 8 3
FIRST TEST REPORT TIME
[Day 00; hour 12; min 00] Days 01-07 Hours 00-23 Min 00-59;
00 in all boxes=instant (Day 01= Monday)
* 8 4
SWINGER SUPPRESSION
* 8 5
ENABLE DIALER REPORTS
FOR PANICS & DURESS
* 8 7
ENTRY WARNING
* 8 8
BURG. ALARM COMM. DELAY
* 8 9
RESTORE REPORT TIMING
0=instant; 1=at bell timeout; 2=at disarm
* 9 0
2nd SUBS. ACCT #
2nd Page Programming Fields
ASSIGN RESPONSE TYPE FOR ZONES
(Enter 00-10; see Response Types below)
1*01
1*02
1*03
28
|
33
|
41
29
|
34
|
42
30
|
35
|
43
31
|
36
|
44
32
|
37
|
45
38
|
46
39
|
47
40
|
48
1*06
1*07
1*08
65
|
73
|
81
66
|
74
|
82
67
|
75
|
83
68
|
76
|
84
69
|
77
|
85
70
|
78
|
86
71
|
79
|
87
72
|
80
|
RESPONSE TYPES: 00 = Disabled zone; 01 = Entry/Exit #1; 02 =
Entry/Exit #2; 03 = Perimeter; 04 = Interior Follower; 05 = Day/Night;
06 = 24 hour Silent Alarm; 07 = 24 hour Audible Alarm; 08 = 24 hour
Auxiliary; 09 = Fire; 10 = Interior, Delay; 20=arm stay; 21=arm away;
22=disarm; 23=no alarm response
NOTES: If using 1 or 2 RF RCVRs, enable their respective faults (88-91)
as troubles (type 5) to provide trouble annunciation. Enter 00 if no
annunciation is desired. 88 & 90 = RCVR not receiving transmitter signals.
89 & 91 = RCVR not responding, bad conn. to panel.
1 * 1 7
LOBBY PARTITION
Enter the "common lobby" partition (1-8)
1 * 1 8
AFFECTS LOBBY
1 * 1 9
ARMS LOBBY
|
|

Partition-Specific

Partition-Specific
Partition-Specific
Partition-Specific
[0]
Partition-Specific
(press *94)
1*04
1*05
|
49
|
57
|
|
50
|
58
|
|
51
|
59
|
|
52
|
60
|
|
53
|
61
|
|
54
|
62
|
|
55
|
63
|
|
56
|
64
|
1*09
|
88
|
2nd RCVR
|
89
|
2nd RCVR
|
90
|
1st RCVR
|
91
|
1st RCVR
|
|
|
Voice Module
[0]
Partition-Specific
Partition-Specific
|
1 * 2 0
EXIT ERROR LOGIC
1=Enable (E/E and Interior zones will be bypassed if faulted
after exit delay);
1 * 2 1
EXIT DELAY RESET
0=No; 1=Resets Exit Delay to 60 seconds after
zone is closed.
FIELDS 1*22-1*25: Allow four sets of two zones each to be
linked so that both must fault within a five minute period to
cause an alarm.
1 * 2 2
CROSS-ZONING PAIR ONE
1 * 2 3
CROSS-ZONING PAIR TWO
1 * 2 4
CROSS-ZONING PAIR THREE
1 * 2 5
CROSS-ZONING PAIR FOUR
1 * 2 8
RF TX LOW BATTERY SOUND
1=immediate; 0=when disarmed; Must be "1" for UL
1 * 2 9
RF TX LOW BATTERY REPORT ENABLE
1=enable; 0=disable
Must be "1" for UL
1 * 3 0
RF RCVR CHECK-IN INTERVAL
02-15 times 2 hours; 00 disables supervision
Max. "6" (12 hr) for UL
1 * 3 1
RF TRANSMITTER CHECK-IN INTERVAL[12]
02-15 times 2 hours; 00 disables transmitter supervision
Max. "6" (12 hr) for UL
1 * 3 2
RF RECEIVER TYPE
1=4281 ( must have correct revision level); 2=5881
1 * 3 3
TOUCH-TONE W/ROTARY BACKUP
1=enable; 0=disable
1 * 3 4
COMM. SPLIT REPORT SELECTION
0=no; 1=alarms primary, others secondary;
2=open/close, test secondary, others primary; See *51 for
comments.
ALARM REPORT CODE & ID DIGITS FOR ZONES
65-80 & SUPV. & RESTORE CODES
1*35 CODE
1*36 ID
65
|
|
66
|
|
67
|
|
68
|
|
69
|
|
70
|
|
71
|
|
72
|
|
0=Disable
|
|
|
|
[06]
[codes default to zero]
1*37 CODE
1*38 ID
1*39
73
|
|
|
74
|
|
|
75
|
|
|
76
|
|
|
77
|
|
|
78
|
|
79
|
|
80
|
|
[0]
[0]
|
|
|
|
[0]
[0]
|
|
[0]
[0]
[0]
Alarm Rst.
Trouble
Trble Rst.
Bypass
Byps Rstt
– 15 –