Partition-Specific - ADEMCO VISTA-50P Quick Start Manual

Partitioned security system with scheduling, step-by-step programming procedure, single and multiple partition programming forms system worksheets
Hide thumbs Also See for VISTA-50P:
Table of Contents

Advertisement

NON-ALARM DIALER CODES
1*40
First Digit
Armed STAY
Time/Date set or event log reset
Event log 50% & 90% full
Event log overflow
Exit Error (Zone)
Exit Error (User)
Recent Close
1 * 4 2
CALL WAITING DEFEAT
1=Yes; 0=No
1 * 4 3
PERM. KEYPAD BACKLIGHT
1 * 4 4
WIRELESS KEYPAD
TAMPER DETECT ENABLE
1 * 4 5
EXIT DELAY SOUNDING
1 * 4 6
AUXILIARY OUTPUT MODE
0=ground start; 1=open/close trigger; 2=keypad sounding;
3=AAV trigger
1 * 4 7
CHIME ON EXT. SIREN
1 * 4 8
WIRELESS KEYPAD ASSIGNMENT
0=disable; enter partition in which RF keypad used, 1-8.
1 * 4 9
SUPPRESS TX SUPERVISION SOUND
1=disable; 0=enable. Must be "0" for UL.
1 * 5 2
SEND CANCEL IF ALARM + OFF
1 * 5 3
DOWNLOAD CALLBACK
1=callback not required; 0=callback required; Must be "0" forUL.
– 16 –
( Armed Stay, Time Set & Event Logging)
1*41
Second Digit
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[0]

Partition-Specific

[0]
1=enable; 0=disable
Partition-Specific
[0]
Partition-Specific
[0]
[1]
Partition-Specific
[0]
1 * 5 7
5800 RF BUTTON GLOBAL ARM
Enter "1" to have the system arm/disarm following the button
user's global arm settings. Enter "0" if the button is not to be
used to global arm the system.
1 * 5 8
5800 RF BUTTON FORCE ARM
Enter "1" to enable. If a zone is faulted after pressing button,
keypad will beep once. User should press button again within
4 sec. to force arm. Enter "0" to disable.
Must be disabled for UL Listed installations.
1 * 6 0
ZONE 5 AUDIO ALARM VERIFICATION
Enter 1 if 2-way audio (AAV) is being used; Enter 0 if it
is not.
1 * 7 0
EVENT LOG TYPES
1=enable logging; 0=disable Alrm
1 * 7 1
12/24 HOUR TIME STAMP FORMAT
0=12 hour; 1=24 hour
1 * 7 2
EVENT LOG PRINTER ON-LINE
0=disable; 1=enable
1 * 7 3
PRINTER BAUD RATE
1 * 7 4
RELAY TIMEOUT XX MINUTES
Enter the relay timeout, 0-127 in multiples of 2 minutes, desired
for #80 Menu Mode time driven event relay command numbers
"04/09" and #93 Menu Mode Relay Programming output
command "56".
1 * 7 5
RELAY TIMEOUT YY SECONDS [000]
Enter the relay timeout, 0-127 seconds, desired for #80 Menu
Mode time driven event relay command numbers "05/10" and
#93 Menu Mode Relay Programming command "57".
1 * 7 6
ACCESS CONTROL RELAY FOR
PARTITION
[0]
[0]
[0]
Chck
Byps
O/C Systm
[0]
[0]
[0]
1=300; 0=1200
[000]
|
|
|
|
Partition-Specific

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-50pul

Table of Contents