SMIS(config)# end
SMIS# show ntp
[NTP] ntp is disabled
Server
=============== ===== ======
200.200.200.10
100.100.100.1
Key # Key
======= ====================================
Time zone offset not set
1.5.2 Enable/Disable NTP
NTP is disabled by default in Supermicro switches.
Follow the below steps to enable NTP.
Step Command
Step 1
configure terminal
Step 2
ntp enable
end
Step 3
Step 4
show ntp
Step 5
write startup-config
The "ntp disable" command disables NTP in the switch. NTP can be enabled in Supermicro
switches only after configuring at least 1 NTP server.
The example below shows the commands used to configure NTP.
SMIS# configure terminal
SMIS(config)# ntp enable
SMIS(config)#end
SMIS# show ntp
[NTP] ntp running unicast mode
Server
Key Prefer
Key
Prefer
100
YES
500
Supermicro L2/L3 Switches Configuration Guide
Description
Enters the configuration mode.
Enables NTP in the switch.
Exits the configuration mode.
Displays the NTP configuration.
Optional step – saves this configuration
to be part of the startup configuration.
34