Genie S-65 Operator's Manual page 4

Boom lift
Hide thumbs Also See for S-65:
Table of Contents

Advertisement

Operator's Manual
SAFETY RULES
Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Maintain safe distances from electrical power lines
and apparatus in accordance with applicable
governmental regulations and the following chart.
Voltage
Phase to Phase
0 to 300V
300V to 50KV
50KV to 200KV
200KV to 350KV
350KV to 500KV
500KV to 750KV
750KV to 1000KV
2
Minimum Safe
Approach Distance
Feet
Meters
Avoid Contact
10
3.05
15
4.60
20
6.10
25
7.62
35
10.67
45
13.72
Genie S-60 & Genie S-65
Third Edition • Second Printing
Allow for platform movement, electrical line sway or
sag and beware of strong or gusty winds.
Keep away from the machine if it contacts
energized power lines. Personnel on the ground or
in the platform must not touch or operate the
machine until energized power lines are shut off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity.
Maximum platform capacity
Maximum platform capacity
S-60 with 6 Ft Platform
with proper counterweight
configuration
Maximum occupants
500 lbs
227 kg
750 lbs
340 kg
2
Part No. 82407