OPERATING INSTRUCTIONS

MATCHING REMOTE
HANDSET & CONTROL
BOX ID CODE
The Remote Control Handset has a set of
unique ID codes that is pre-programmed into its
memory. This set of ID codes helps to differenti-
ate one Remote Control Handset from another
so that only the control box with a matching ID
code will respond to the appropriate Remote
Control Handset.
To ensure the remote control is matched to
the receiver correctly, please follow the steps
below:
1. Ensure that the Remote Control and the
3-way switch located at the appliance are
both in the OFF position.
2. Ensure that the pilot is lit and the pilot
control knob is in the ON position on the
appliance.
3. Install the 2 x AAA alkaline batteries into the
Remote Control.
4. Unplug and re-plug the power cord. The
power cord is located on the left hand side
of the appliance and will be plugged into the
receptacle.
5. Switch the 3-way switch located on the ap-
pliance to the REMOTE position.
6. Press and hold the PROG and FAN buttons
simultaneously for up to 20 seconds. During
this time, the remote will display LC while it
is transmitting codes to the receiver. Once
it is successfully transmitted, one will hear
the solenoid click and the burners will come
on. If is does not work the fi rst time, repeat
steps 1 - 6.
7. Release both the PROG and FAN buttons.
The remote will revert back to normal, but
the burner will still be on.
8. Press the ON/OFF button on the remote
control 2 times to turn the burner off.
9. The remote control is now programmed to
the receiver and the appliance can now be
operated with it.
The control box will only learn the Remote ID
codes during the fi rst 30 seconds after power
is applied and will ignore this special command
from the Remote after the fi rst 30 seconds.
NOTE: This must only be performed by a quali-
fi ed installer.
40
OPERATING
INSTRUCTIONS
1) Read and understand these instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the glass in the door frame is
properly positioned. Never operate the
appliance with the glass removed.
5) Verify that the venting and cap are
unobstructed.
6) Ensure that the brick panels are installed.
7) Verify log placement. If the pilot cannot be
seen when lighting the unit, the logs have
been incorrectly positioned.
8) The unit should never be turned off, and on
again without a minimum of a 60 second
wait.
LIGHTING
PROCEDURE
IMPORTANT
To ignite or reignite the pilot,
you must fi rst release the
tension springs below the door.
Only when the pilot holds, without pressure
being applied to the control knob, reapply the
tension springs to the door. The unit must
not be operated with the tension springs
unattached.
IMPORTANT Gas on/off knob cannot be
turned from "PILOT" to "OFF" unless it is
partially depressed.
Ensure that the 3 way switch on the manual
control panel is in the "Remote" position.
Manual Control Panel
3-way Switch
1) Push in gas control knob slightly and turn
clockwise to "OFF". Knob cannot be turned
from "PILOT" to "OFF" unless knob is pushed
in slightly. Do not force.
2) Wait fi ve (5) minutes to clear out any gas.
3) Turn knob on gas control counterclockwise
to "PILOT".
4) Push in control knob all the way and hold in
until the pilot lights up. Continue to hold the
control knob in for about 20 seconds after
the pilot is lit. Release knob and it will pop
back up. Pilot should remain lit. If it goes out,
repeat steps 1) to 4). If knob does not pop
up when released, stop and immediately
call your service technician or gas supplier.
If the pilot will not stay lit after several tries,
turn the gas control knob to "OFF" and call
your service technician or gas supplier.
5) Turn gas control knob counterclock-wise to
"ON".
6) Turn the unit on.
NOTE: If using the remote control refer to
the FireWizard manual for instructions.
SHUTDOWN
PROCEDURE
1) Press the ON/OFF switch once.
2) The LED will fl ash.
3) Turn the main gas control clockwise to the
"OFF" position to turn off the pilot.
4) Turn off all electric power to appliance if
service is to be performed.