INSTALLATION
These venting systems, in combination with the P40 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by
Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent
Termination Requirements" section.
Regency
®
Direct Vent (Flex) System
Termination Kit (Part# 946-618) includes all
the parts needed to install the P40 with a
maximum run of 6 feet.
1) 8" dia. fl exible liner (6 ft. length)
2) 5" dia. fl exible liner (6 ft. length)
3) spring spacers (4)
4) thimble
5) AstroCap XL termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" Drill Point,
Stainless Steel (4)
10) vinyl siding standoff
If longer runs are needed, the Regency
Vent system (Flex) Part# 946-616 includes
all the parts needed to install the P40 with a
maximum 10' run.
1) 8" dia. fl exible liner (10 ft. length)
2) 5" dia. fl exible liner (10 ft. length)
3) spring spacers (7)
4) thimble (2)
5) AstroCap XL termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" Drill Point,
Stainless Steel (4)
10) vinyl siding standoff
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from FPI may be used for Flex installations.
3) Horizontal vent must be supported every 3 feet. (For 10' fl ex kit 946-616 only.)
14

VENTING ARRANGEMENTS

HORIZONTAL TERMINATION (FLEX)

Regency
Direct Vent System
®
Wall Thimble
(required in Canada only)
5" dia. flue pipe
8" dia.
Flue pipe
®
Direct
AstroCap XL
(Part# 946-623/P)
Vinyl Siding
Standoff
spring spacer
Regency
®
P40-1 Direct Vent Gas Fireplace