The shaded area in the diagram shows all allowable
combinations of straight vertical and offset to vertical
terminations, using two 90
o
elbows, with Rigid Pipe
Venting Systems for Propane and Natural Gas.
Two 45
elbows equal to one 90
o
o
of four 45
elbows allowed.
o
•
Vent must be supported at offsets.
•
Firestops are required at each fl oor level and
whenever passing through a wall.
•
Maintain clearances to combustibles as listed
in the "Clearances" section.
•
Refer to "Vent Restrictor Position" section for
details on how to change the vent restrictor
to Set 1 or Set 2 if required.
Note: Must use optional fl ue adapter when using
Rigid Pipe (Part # 770-994).