Perform Hydraulic Oil Analysis - Genie S-65 Service Manual

Hide thumbs Also See for S-65:
Table of Contents

Advertisement

Section 3 • Scheduled Maintenance Procedures
CHECKLIST B PROCEDURES
3 S-65: Move the function enable/rpm select
toggle switch to either side and activate the jib
boom toggle switch in the down position, hold
for a moment and then release it.
Result: The descent alarm should sound when
the switch is held down.
4 Turn the key switch to platform control.
Result: The flashing beacon should be on
and flashing.
5 Press down the foot switch. Move the boom
control handle to the down position, hold for a
moment and then release it.
Result: The descent alarm should sound when
the control handle is held down.
6 S-65: Press down the foot switch. Move the jib
boom toggle switch to the down position, hold
for a moment and then release it.
Result: The descent alarm should sound when
the control handle is held down.
7 Press down the foot switch. Move the drive
control handle off center, hold for a moment and
then release it. Move the drive control handle off
center in the opposite direction, hold for a
moment and then release it.
Result: The travel alarm should sound when the
drive control handle is moved off center in either
direction.
3 - 28
B-18

Perform Hydraulic Oil Analysis

Replacement or testing of the hydraulic oil is
essential for good machine performance and
service life. Dirty oil and a clogged suction strainer
may cause the machine to perform poorly and
continued use may cause component damage.
Extremely dirty conditions may require oil changes
to be performed more often.
S-60 • S-65
Before replacing the hydraulic oil,
the oil may be tested by an oil
distributor for specific levels of
contamination to verify that
changing the oil is necessary. If
the hydraulic oil is not replaced
at the two year inspection, test
the oil quarterly. Replace the
oil when it fails the test.
See E-1, Test or Replace the
Hydraulic Oil.
Part No. 77828
July 2005
REV C

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-60

Table of Contents