Control System Commands

The H-ADCP uses the following commands to control certain system parameters.

Available Control System Commands

This section lists the available Control System commands.
>c?
CB = 611 ----------------- Serial Port Control (Baud [6=38400]; Par; Stop)
CF = 11110 --------------- Flow Ctrl (EnsCyc;PngCyc;Binry;Ser;Rec)
CG = 0 ------------------- Swap Beams 1 & 2 (0 = Disable, 1 = Enable)
CK ----------------------- Keep Parameters as USER Defaults
CL = 1 ------------------- Sleep Enable (0 = Disable, 1 = Enable)
CM = 0 ------------------- RS-232 Sync Master (0 = OFF, 1 = ON)
CN = 1 ------------------- Save NVRAM to recorder (0 = ON, 1 = OFF)
CP = 0 ------------------- PolledMode (1=ON, 0=OFF;
CQ = 255 ----------------- Xmt Power (0=Low, 255=High)
CR # --------------------- Retrieve Parameters (0 = USER, 1 = FACTORY)
CS ----------------------- Go (Start Pinging)
CY # --------------------- Error Status Word (0=Clear, 1=Display)
CZ ----------------------- Power Down Instrument
>

Control System Command Descriptions

CB - Serial Port Control

Purpose
Sets the RS-232/422 serial port communications parameters (Baud Rate/Parity/Stop
Bits).
Format
CBnnn
nnn = baud rate, parity, stop bits (see description)
Range
Default
CB411
Recommended Setting. The default setting for this command is recommended for most applications.
Description
The H-ADCP and your external device (dumb terminal, computer software) MUST use
the same communication parameters to talk to each other. After you enter valid CB pa-
rameters, the H-ADCP responds with a ">" prompt. You may now change the external de-
vice's communication parameters to match the H-ADCP parameters before sending an-
other command. See
change the Baud rate using BBTalk.
Table 16:
Serial Port Control
Baud Rate
0 = 300
1 = 1200
2 = 2400
3 = 4800
4 = 9600 (Default)
5 = 19200
6 = 38400
7 = 57600
8 = 115200
Changing the Baud Rate in the H-ADCPs
Parity
1 = None (Default)
2 = Even
3 = Odd
4 = Low (Space, logical 0)
5 = High (Mark, logical 1)
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
BREAK resets)
for instructions on how to
Stop Bits
1 = 1 Bit (Default)
2 = 2 Bits
May 2015
Page 139