Configuring The Synchronous Wan Port - Lucent Technologies PortMaster 4 Configuration Manual

Table of Contents

Advertisement

5. Save the configuration.
Command> save all
6. Reset the slot.
Command> reset slot10

Configuring the Synchronous WAN Port

Follow this procedure to configure the synchronous WAN port on the PortMaster 4 for
leased line service:
1. Enter the show boards command to determine the identification number of
the line board you want to configure.
The board identification number is the same as the number of the slot in which the
T1 or E1 module is installed.
Command> show boards
2. Set the view to a slot with an installed T1 or E1 line board.
Setting the view for a specific board gives you administrative access to that board.
Command> set view Slotnumber
Command Slotnumber>
The slot number appears in the prompt to identify the board you are configuring.
3. Set a line on the line board for T1 or E1.
Command Slotnumber> set Line0 t1|e1
4. Save the configuration.
Command Slotnumber> save all
5. Reset the slot.
Command Slotnumber> reset Slotnumber
6. Set the interface for network hardwired.
Command Slotnumber> set W1 network hardwired
7. Set the protocol.
Command Slotnumber> set W1 protocol ppp
8. Set the destination IP address.
If you are not sure of the IP address on the other end of the connection, you can set
the IP destination to 255.255.255.255 and the PortMaster attempts to learn the
address.
Command Slotnumber> set W1 destination Ipaddress
Using Synchronous Leased Lines
Configuring a Leased Line Connection
13-3

Advertisement

Table of Contents
loading