9. Save the configuration to nonvolatile RAM.
Command 0> save all
10. Reset the slot.
Command 0> reset slot0
11. Repeat the previous 10 steps for each installed Quad T1 board.
You must change the view to the appropriate slot.

Configuring General Settings

Configure the following general settings for T1, E1, or ISDN PRI lines on PortMaster 4.

Setting the View

To configure a T1, E1, or ISDN PRI line, you must first set the view. Enter the show
boards command to determine the identification number of the line board you want to
configure.
The board identification number is the same as the number of the slot in which the T1
or E1 board is installed.
Command> show boards
Use the following command to set the view to a slot with an installed T1 or E1 line
board:
Command> set view Slotnumber
Setting the view for a specific board gives you administrative access to that board.

Displaying Line Status

To display the status of a E1 or T1 line, use the following command:
Command> show Line0

Configuring Line Use

You can use a line as a single E1 or T1 line; as PRI B channels; as a fractional E1, ISDN,
or T1 line divided into channel groups; or for in-band signaling for channelized T1 or
E1.
Note – T1 and E1 lines require an external clock signal provided by the device to which
the PortMaster is connected, or by the telephone company network.
Configuring T1, E1, and ISDN PRI

Configuring General Settings

10-5