Configuring a T1 or E1 Line for Frame Relay

Configuring the Synchronous WAN Port

Follow this procedure to configure the synchronous WAN port on the PortMaster 4:
1. Enter the show boards command to determine the identification number of
the line board you want to configure.
The board identification number is the same as the number of the slot in which the
T1 or E1 module is installed.
Command> show boards
2. Set the view to a slot with an installed T1 or E1 line board.
Setting the view for a specific board gives you administrative access to that board.
Command> set view Slotnumber
Command Slotnumber>
The slot number appears in the prompt to identify the board you are configuring.
3. Set the network type.
Command Slotnumber> set W1 network hardwired
4. Set the protocol.
Command Slotnumber> set W1 protocol frame
5. Set the IP address of the port.
Command Slotnumber> set W1 address Ipaddress
6. Set the netmask.
Command Slotnumber> set W1 netmask Netmask
7. Monitor the carrier detect signal.
Command Slotnumber> set W1 cd on
8. Enable RIP on the interface.
Command Slotnumber> set W1 rip broadcast
9. Set the Annex-D polling interval.
You can use LMI instead of Annex-D.
Command Slotnumber> set W1 annex-d Seconds
10. Add a data link connection identifier (DLCI).
You do not need to set a DLCI list if the remote router supports Inverse ARP.
Command Slotnumber> add dlci W1 Dlci :Ipaddress