8. Set the netmask of Ether1.
Command> set ether1 netmask 255.255.255.0
9. Set Ether1 broadcast to high.
Command> set ether1 broadcast high
10. (Optional) Set Ether0 to listen for and broadcast RIP-1 packets.
Command> set ether1 rip on
11. Save the settings and reset the slot.
Command> save all
Command> reset slot10
12. Set the default gateway address.
Command> set gateway 192.168.100.254
Proceed to global configuration.

Configuring Global Parameters

You can now connect to the PortMaster 4 via Telnet or PMVision to continue the
configuration process. You can perform the following command line configuration via
the console or by using Telnet. Substitute your own information for variables.
1. If you are not already in slot 4, set the view to slot 4.
Command> set view 4
2. Set the IP address for syslog authentication information.
Command> set loghost 192.168.1.2
3. (Optional) Set a domain name.
Command> set domain ISP.net
4. (Optional) Set the Domain Name System (DNS).
Command> set namesvc dns
5. (Optional) Set the IP address of the name server.
Command> set nameserver 192.168.25.16
6. (Optional) Set RIP broadcast to high.
Command> set ether0 broadcast high
7. Do not broadcast default routes.
Command> set default off
8. Set the IP address of the RADIUS server.
Command> set authentic 192.168.120.10
Configuring T1, E1, and ISDN PRI