Table 10-2
Option
Cgroup
Channel-list

Setting the Channel Rate

Table 10-3
following command. Table 10-4 explains the channel rate options.
Command> set Line0 group Cgroup 56k|64k
Table 10-4
Option
Line0
Cgroup
56k
64k

Configuring ISDN PRI Settings

Use the following settings to configure ISDN PRI on the PortMaster 4.

Setting the ISDN PRI Switch

The switch type information is available from your ISDN PRI service provider. To set the
switch type for ISDN connections to the PortMaster ISDN PRI virtual ports, use the
following command—entered on one line. Table 10-5 explains the ISDN switch options.
Command> set isdn-switch ni-2|dms-100|4ess|att-5ess
|net5|vn2|vn3|1tr6|ntt|kdd|ts014
Table 10-5
ISDN Switch
ni-2
dms-100
4ess
att-5ess
Configuring T1, E1, and ISDN PRI
Channel Group Options (Continued)
Description
Group number from 1 to 63 that designates a port number
on each T1, E1, or ISDN PRI line, or none to unassign
channels.
Space-separated list of one or more channel numbers,
from 1 through 24 for T1, or 1 through 30 for E1. The
channel numbers do not have to be contiguous.
To set the channel rate to 56Kbps or 64Kbps for a channel group, use the
Channel Rate Options
Description
Line0 through Line3 (T1), Line0 through Line2 (E1).
Defined channel group from 1 to 63.
56Kbps, typically used for D4 framing.
64Kbps, used for framing types other than D4. This is the
default.
ISDN Switch Options
Description
National ISDN-2 (NI-2) compliant. This is the default.
Northern Telecom DMS-100 Custom.
AT&T 4ESS.
AT&T 5ESS.

Configuring ISDN PRI Settings

10-7