Before you configure a line for Frame Relay, you must configure global settings on the
PortMaster 4, set the gateway routers, and configure the Ethernet interface. Follow the
procedures in this section to configure a T1 or E1 line for Frame Relay service.

Configuring Global and Ethernet Settings

You configure global and Ethernet settings on the PortMaster 4 from the manager
module (slot 4), which is the default view. See Chapter 2, "Configuring Global Settings,"
and Chapter 4, "Configuring an Ethernet Interface," for more information.
Note – Lucent recommends that you configure Ether1 if you configure only one
Ethernet interface. If you configure both, you must connect them to separate Ethernet
segments. Ether0 operates at 10Mbps and is physically on the manager board. Use
Ether1 for netboots, SNMP, RADIUS, and syslog.
Follow this proceduG8e to configure the global and Ethernet settings on the PortMaster
4.
1. Set the IP address of the gateway router.
Command> set gateway Ipaddress
2. Save the configuration to nonvolatile RAM.
Command> save all
3. Set the IP address of the Ethernet interface.
Command> set ether1 address Ipaddress
4. Set the netmask of the Ethernet interface.
Command> set ether1 netmask Netmask
5. Set broadcast to high.
Command> set ether1 broadcast high
6. Enable RIP routing on the interface.
Command> set ether1 rip on
7. Save the configuration to nonvolatile RAM.
Command> save all
8. Reset the slot
Because the Ethernet board on the manager module is in logical slot 10, you
activate the Ether1 configuration by resetting slot 10.
Command> reset slot10
Using Frame Relay
Configuring a T1 or E1 Line for Frame Relay
12-5