Note: There must be enough DN's available in the system to populate the
entire Norstar Expansion Module being configured, otherwise you will not be
able to configure the module and it will not function.
Note: There must be enough consecutive line numbers available in the
system to populate the entire Norstar Expansion Module being configured,
otherwise you will not be able to configure the module and it will not function.
Note: Received Digits and OLI settings can be configured in other areas of
Element Manager, such as Telephony, Active Sets. However, configuring
these settings in Telephony Resources is a convenient and time saving
method, if feasible on your installation.
9. Click on OK when you have entered the required settings.
10. The FEM dip switches should be set to all On.
11. The full ranges of extensions or lines associated with each Norstar
Extension Module are listed in the Low and High columns. This may
be useful to note for reference purposes.
12. The BCM should now be shut down to allow FEM MBM installation. All
the FEM dip switches should be set to On.
Note: Do not install MBM's whilst the BCM is powered up.
NN40010-317 Issue 1.2 BCM450 Rls 6.0
BCM450 System Start Up
87