Control Center Assembly - Graco PCF Instructions - Parts Manual

Precision dispense system
Hide thumbs Also See for PCF:
Table of Contents

Advertisement

Repair

Control Center Assembly

Prepare Control Center for Repair
1. Power off the display.
2. Disconnect main power to the control center assem-
bly.
3. Remove the control center assembly front cover
(20).
Replace Gateway Module
1. Prepare Control Center for Repair, page 74.
2. Remove the automation communications cable
(AE).
3. Remove the two screws holding the Gateway mod-
ule (5) to the base (3), and remove the module.
F
. 50
IG
4. Attach a new Gateway module to the base using
two screws.
5. Reconnect the automation interface cable.
74
Replace Gateway Module Base
1. Prepare Control Center for Repair, page 74.
2. Remove the Gateway module (5); follow Replace
Gateway Module. (Leave automation communica-
tions cable (AE) attached to Gateway module.)
3. Disconnect the CAN cable (19) and power supply
cable (6) from the base (3).
4. Remove the four screws (16) and grounding screw
(12) from the base and replace it with a new base.
F
. 51
IG
5. Secure the new base to rear cover (1) using the five
screws.
3
6. Reattach Gateway module; follow Replace Gate-
way Module.
5
6
3
12
5
1
19
16
4
313377L

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents