Cgm I/O Data Map - Graco PCF Instructions - Parts Manual

Precision dispense system
Hide thumbs Also See for PCF:
Table of Contents

Advertisement

Appendix C - Communications Gateway Module (CGM) Connection Details

CGM I/O Data Map

Automation Inputs (signals from PCF)
Byte
Input Bit
I00
0
I01
I02
I03
I04
I05
I06
I07
Dispenser Remote Start / Purge In
I08
1
I09
I10
I11
I12
I13
I14
I15
I16
2
I17
I18
I19
I20
I21
I22
I23
I24
3
I25
I26
I27
I28
I29
I30
I31
I32
4
I33
I34
I35
I36
I37
I38
I39
108
Description
Dispenser Ready
Dispenser No Alarm
Dispense No Error
Dispense in Process
Dispense Volume OK
(Spare)
Dispenser Purge Request
Process
Pressure Units - Bit 0
Pressure Units - Bit 1
Error - 1
Error - 2
Error - 4
Error - 8
Error - 16
Error - 32
Error - 64
Error - 128
Dispensed Volume - 1
Dispensed Volume - 2
Dispensed Volume - 4
Dispensed Volume - 8
Dispensed Volume - 16
Dispensed Volume - 32
Dispensed Volume - 64
Dispensed Volume - 128
Byte
Input Bit
I40
5
I41
I42
I43
I44
I45
I46
I47
I48-I55
6
I56-I63
7
I64-I71
8
I72-I79
9
I80-I87
10
I88-I95
11
I96-I103
12
I104-I111
13
I112-I119
14
I120-I127
15
I128
16
I129
I130
I131
I132
I133
I134
I135
I136
17
I137
I138
I139
I140
I141
I142
I143
I144-I151
18
I152-I159
19
I160
20
I161
I162
I163
I164
I165
I166
I167
Description
Dispensed Volume - 256
Dispensed Volume - 512
Dispensed Volume - 1024
Dispensed Volume - 2048
Dispensed Volume - 4096
Dispensed Volume - 8192
Dispensed Volume - 16384
Dispensed Volume - 32768
Inlet Pressure - 1
Inlet Pressure - 2
Inlet Pressure - 4
Inlet Pressure - 8
Inlet Pressure - 16
Inlet Pressure - 32
Inlet Pressure - 64
Inlet Pressure - 128
Inlet Pressure - 256
Inlet Pressure - 512
Inlet Pressure - 1024
Inlet Pressure - 2048
Inlet Pressure - 4096
Inlet Pressure - 8192
Inlet Pressure - 16384
Inlet Pressure - 32768
Outlet Pressure - 1
Outlet Pressure - 2
Outlet Pressure - 4
Outlet Pressure - 8
Outlet Pressure - 16
Outlet Pressure - 32
Outlet Pressure - 64
Outlet Pressure - 128
313377L