USB Data

USB Data

USB Logs

During operation, PCF stores system and performance
related information to memory in the form of log files.
PCF maintains three log files: job logs, error logs, and
dispense data logs. Follow the Download Procedure,
page 49, to retrieve log files.
Job Log
The job log file name is 1-JOB.CSV and is stored in the
DOWNLOAD folder.
The job log maintains a record of the last 1,000 jobs. At
the completion of each job the following data is stored in
the log file:
Job completion date
Job completion time
Job number (sequential number)
Style number
Target volume (in units set in the volume units
field)
Requested volume (in units set in the volume
units field)
Actual dispensed volume (in units set in the vol-
ume units field)
Volume units
Error percentage between actual dispensed vol-
ume and requested volume
Minimum inlet pressure during job in units of bar
(heated systems will always read 0)
Average Inlet pressure during job in units of bar
(heated systems will always read 0)
Maximum inlet pressure during job in units of
bar (heated systems will always read 0)
Minimum outlet pressure during job in units of
bar
Average outlet pressure during job in units of
bar
Maximum outlet pressure during job in units of
bar
Minimum flow rate during job in units of cc/min
(systems with no flow meter will read 0)
Average flow rate during job in units of cc/min
(systems with no flow meter will read 0)
Maximum flow rate during job in units of cc/min
(systems with no flow meter will read 0)
Elapsed time
48
Error Log
The error log file name is 2-ERROR.CSV and is stored
in the DOWNLOAD folder.
The error log maintains a record of the last 1,000 errors.
Each error record in the log file contains: the date and
time the error occurred, the error code, and the error
description.
Dispense Data Log
The dispense data log file name is 3-DATA.CSV and is
stored in the DOWNLOAD folder.
The dispense data log maintains a record of system inlet
pressure (heated systems will always read 0), system
outlet pressure, and system flow rate (systems without
flow meters will always read 0). This data is recorded at
one second intervals when a job cycle is in process. The
dispense data log is capable of storing up to two hours
of data.
System Configuration Settings
File
The system configuration settings file name is
SETTINGS.TXT and is stored in the DOWNLOAD
folder.
A system configuration settings file automatically down-
loads each time a USB flash drive is inserted. Use this
file to back up system settings for future recovery or to
easily replicate settings across multiple PCF systems.
Refer to the Upload Procedure, page 50, for instruc-
tions on how to use this file.
NOTE: Do not modify the contents of this file.