Standards; Use In Hazardous Areas; Hw1483325 - YASKAWA DX200 Instructions Manual

For explosion-proof specifications
Hide thumbs Also See for DX200:
Table of Contents

Advertisement

2 Indications on Explosion-Proof Devices
2.2

Standards

The DX200 meets the following requirements:
・ Directive 94/9/EC for equipment and protective systems for proper use in hazardous
areas
・ IEC 60079-0:2011 for electrical apparatus for explosive gas atmospheres Part 0:
General requirements
・ IEC 60079-2:2007 for electrical apparatus for explosive gas atmospheres Part 2:
Pressurized enclosures "p"
・ IEC 60079-11:2011 for electrical apparatus for explosive gas atmospheres Part 11:
Intrinsic safety " i "
・ Machinery Directive 2006/42/EC
・ Low Voltage Directive 2006/95/EC
・ EMC Directive 2004/108/EC
・ EN 1127-1 and EN 13463-1 for hazardous areas
When classifying a manipulator environment as a hazardous area (zone),
observe the "Guidelines for the Avoidance of Dangers due to Explosive
Atmospheres with Collection of Examples - Explosion Protection
Guidelines - (EX-Directives)".
In special cases, or if you are not sure about the specification of areas
with the risk of explosion, contact the competent authorities or Yaskawa
and have them decide.
2.3

Use in Hazardous Areas

Following explosion-proof markings are attached on the painting unit.
Painting Unit [Exib] IIB Gb
Marking
EX
ib
[ ]
IIB
Description
Symbol for explosion-proof devices
Intrinsic safety type of explosion-proof
A marking when the unit is used with approved
devices such as barrier, and has conditional
parts for explosion-proof.
Gas group
.

HW1483325

2-4
174117-1CD
14 /33

Hide quick links: