6 Connection
(2) Explosion proof programming pendant
1.
Connect a ground wire to the ground terminal (for the power supply barrier for
explosion proof programming pendant) on the back side of the DX200 painting unit.
・ Ground resistance to be connected to the backside of the painting unit must be
10 ohms or less with independent ground connection.
The performance of explosion proof programming pendant cannot be maintained.
The customer must prepare the ground wire.
2. Connect the explosion proof programming pendant cable to the connector on the door
of the DX200 painting unit.
MANDATORY
6-6
174117-1CD
.
HW1483325