9 Maintenance

9 Maintenance
9.1

Maintenance for DX200

• Turn OFF the power supply before opening the DX200 doors.
Failure to observe this warning may result in electric shock.
• To prevent anyone inadvertently turning ON the power supply during
maintenance, put up a warning sign such as "DO NOT TURN ON THE POWER" at
the primary power supply (knife switch, wiring circuit breaker, etc.) and at the
DX200 and related controllers and use accepted lockout/tag out Procedures.
Failure to observe this caution may result in electric shock or injury.
• After maintenance is completed, carefully check that no tools are left inside the
DX200 and that the doors are securely closed.
Failure to observe this caution may result in electric shock or injury.
ITEM
1 DX200 Front door
2 DX200 Front door Gasket
3 Fan inside the DX200
4 Duct fan back side of the DX200
5 Heat exchanger fan
Emergency stop button
6
Programming Pendant
7 Enable switch
8 Battery
9 Power supply
10 Intrinsically satety cable
11 Power supply cable
Relay Barrier
12
(inside the painting unit)
Isolated Barrier
13
purge control board
14
JARCR-YIS21
(inside the painting unit)
encoder separation board note.1)
15
JARCR-YIS22
(back side inner painting unit)
encoder separation board note.1)
16
JARCR-YIS23
(back side inner painting unit)
Note.1:Even if the encoder separating board is functioning normally,it is recommended to replace it in 36000H cycle.
WARNING
Schdule
Method
Visually
Visually
Visually
Visually
Visually
Press thebutton after servo power
is turned on
check that the enable switch
functions securely (progarmming
pendant)
Visually(progarmming pendant)
check for the power supplying
valtage (use a tester)
Visually ,Manually
Visually ,Manually
Visually
Visually
Visually
Visually
Visually
9-1
Operation
Refar to the
DX200 MAINTENANCE MANUAL
check for off ,loose connection, or no
disconnection of the connectors pr lead wires
check for off ,loose connection, or no
disconnection of the connectors pr lead wires
check for exterior damages.
Check for massage saying "purge error" on the
programming pendant window.
If the massage is the displayed,refer to the DX200
MAINTENANCE MANUAL.
If it is not solved, contact your yaskawa
representative
check for exterior damages.
Check for massage saying "purge error" on the
programming pendant window.
If the massage is the displayed,refer to the DX200
MAINTENANCE MANUAL.
If it is not solved, contact your yaskawa
representative
check for exterior damages.
Check for massage saying "purge error" on the
programming pendant window.
If the massage is the displayed,refer to the DX200
MAINTENANCE MANUAL.
If it is not solved, contact your yaskawa
representative
check for exterior damages.
Check for massage saying "purge error" on the
programming pendant window.
If the massage is the displayed,refer to the DX200
MAINTENANCE MANUAL.
If it is not solved, contact your yaskawa
representative
check for exterior damages.
Check for massage saying "purge error" on the
programming pendant window.
If the massage is the displayed,refer to the DX200
MAINTENANCE MANUAL.
If it is not solved, contact your yaskawa
representative
HW1483325
174117-1CD