5 Installation
5.3

Installation Method

• Do not climb on top of the DX200.
Failure to observe this caution may result in injury or damage.
Fix the DX200 to the floor or baseplate by using four user-supplied
brackets made according to the specifications shown below.
If casters are attached, fix the DX200 in the same way.
φ14
(2 holes)
40
40
(unit:mm)
※1 :Fixing JIG is different with specification.
For detail ,see the following.
Specification
Standard, with transformer
with caster
Recommended Controller fixing screw: M12 (length: 20 mm) Tightening torque (45N・m (4.6kgf・m
Recommended plate thickness :6 mm
Note.: Choose screw length in considering effective screw 14mm in depth of
the fixed screw in the side panel.
Anchor bolt: M12
CAUTION
※1
Tapped holes for
M12 screws on
B
The DX200 side
B
A
A
30
40
50
50
40
145
(unit: mm)
5-3
60
165
.
HW1483325
174117-1CD
2
))
19/33