Inspections; Regular Inspection Item - YASKAWA DX200 Instructions Manual

For explosion-proof specifications
Hide thumbs Also See for DX200:
Table of Contents

Advertisement

8 Inspections

8 Inspections
8.1

Regular Inspection Item

NO.
Item
1
DX200 front door
Fan
-Inside the DX200
2
-Duct fan at the backside
-Heat exchanger
3
Emergency stop button
4
Enable switch
5
Battery
6
Power supply
Lead wires for the
7
breaker
8
Intrinsically safe cable
9
Power supply cable
10
Relay barrier
11
Isolated barrier
Purge control board
12
JARCR-YIS21
Encoder separating board
13
JARCR-YIS22
Encoder separating board
14
JARCR-YIS23
Note1:This board may be mounted by specification.
Operation
Check whether it is completely
closed.
Check whether the gasket is not
damaged.
Check whether it is functioning
normal.
Check whether it is functioning
normal.
Check whether it is functioning
normal.
Check the message indication
Check the power supplying voltage
(by tester)
Check disconnection or missing of
lead wires, and the screw loose.
Check disconnection or missing of
lead wires, and the screw loose.
Check disconnection or missing of
lead wires, and the screw loose.
Check whether it is functioning
normal.
Check whether it is functioning
normal.
Check whether it is functioning
normal.
Check whether it is functioning
normal.
Check whether it is functioning
normal.
(Note1)
8-1
174117-1CD
Remarks
When the power is turned
ON
When the servo power is
turned ON
When Teach mode is
enabled.
Placed Inside the painting
unit.
Placed Inside the painting
unit.
Placed Inside the painting
unit.
Placed Inside the painting
unit(back side).
Placed Inside the painting
unit(back side).
HW1483325