4-4 Function Mode
SYSTEM REPORT
Turn on the SUB POWER SW
by pressing [
Set Black Ribbon & Media.
Head Temperature
Total Printed Length
Amount set by Print/Cut Offset
Adjustment
Original Amount for Current.
MAX should be smaller MIN.
Eccentric amount for Grit
Eccentricity Adjustment
Serial Number of the HEAD
User DIP SW settings
AGING MODE
Turn on the SUB POWER SW by pressing
[
], [
GRIT ROLLER and TOOL CARRIAGE
start to idle.
Turn off the SUB POWER SW to end.
] keys.
**** PC-60 System Report ****
Version : Firmware= A140
Temperature: Head= 32cel
Record : Print= 3933m
*** Factory settings ***
Offset : Head-X= -7step
Tool Force VR : Max= 776
Solenoid Current : Max= 41
Grit Distance : +8
Eccentricity : Amount- 0
Head ID : B06-0032
Density Adjust : +1 +1
0
:
0
0
0
Stitch Adjust : Upper= 0
On Board Dip-SW : (1) X0XX (4)
*** User settings ***
User Dip-SW : (1) XXXXXXXXXX (10)
Line Space : 0dot
] and [
] keys.
Lower the Sheet Loading Lever to print.
Environment Temperature
Booter= B100
Env.= 26cel
Number of cleaning with Cleaning Sheet
Cleaning= 2
Head-Y= 14step
Holder= -20step
Min= 0
Min= 343
Number= 0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 -1
0
0 -1
Lower= 0
PRINTING TEST
Turn on the SUB POWER SW by
pressing [CUT TEST] keys.
Cuts around C & K.
(
: starting point)
4 Adjustment
Amount set by Cartridge Position
Adjustment
Indicates the position of Slide Volume.
MAX should be bigger than MIN.
Amount for Grit Compensation
Amount set by Density Adjustment
Amount set by Stitching Adjustment
DIP SW settings on Main Board
Amount set by Line Space Adjustment
C
M
B
R
Y
K
C
M
Y K
4