SP5-xxx: Mode
SP5
Mode Number
5024*
mm/inch Display Selection
5044
Operation Panel Bit SW
5104*
A3/DLT Double Count
5106*
6*
ADS Level Selection
5112*
Non-Standard Paper Selection
5113*
Optional Counter Type
5118*
Disable Copying
5120*
Mode Clear Opt. Counter
Removal
5121*
Counter Up Timing
SM
SERVICE PROGRAM MODE TABLES
Function and [Setting]
Selects the unit of measurement.
After selection, turn the main power switch off and
on.
0: Europe/Asia 1: North America
0: mm, 1: inch
DFU
Specifies whether the counter is doubled for
A3/DLT.
0: No
1: Yes
2: Counts once for A4 SEF fed from bypass tray.
!
If
is selected, the total counter counts up twice
when A3 or DLT paper is used.
Selects the image density level used in ADS
mode.
[1~7 / 4 / 1 notch per step]
Example: If you set SP5-106-6 to "2": Pressing the
Auto Image Density key toggles the display off
and manual notch 2 is selected.
Adjust this SP if the customer cannot attain clean
copies after performing automatic density
adjustment.
Determines whether a non-standard paper size
can be initialized for copying or not.
0: No, 1: Yes
If ! is selected, a non-standard size can be input
using the UP mode.
Selects the corresponding key for installed
devices such as a coin lock. Japan only
[0~5 / 0 / 1 step]
0
None.
1
Key card (RK3, RK4)
2
Key card (subtraction count setting)
3
Pre-paid card
4
Coin lock
5
MF key card (Peace) Japan only
11
MF key card (Increment)
12
MF key card (Decrement)
DFU
Clears all coin devices. Japan only
[0~2 / 0 / 1 step]
0: Normal reset.
1: Resets only when job finished or before job
begins.
2: Not normal reset.
Determines whether the optional key counter
counts up at paper feed or at paper exit.
0: Feed, 1: Exit
The total counter is not affected by this SP mode.