1-BIN TRAY UNIT INSTALLATION (B544)
[A]
[C]
2. Unpack the 1-bin tray unit and remove the tapes.
3. Remove the front bracket [A] ( x 1) and rear bracket [B] ( x 1) from the top
of the paper exit cover [C].
4. Remove the paper exit cover [C] ( x 4).
5. Cut away two covers [D] from the base cover [E].
6. Trim the edges so they are smooth.
7. Install the base cover [E] ( x 3: stepped screw).
8. Set the 1-bin tray unit [F] on the base cover and slide onto the heads of the
stepped screws.