Pressure Relief Valve; Thermostat And Manual Reset - Jayco COVE 2002 Owner's Manual

Park trailer
Table of Contents

Advertisement

PRESSURE RELIEF VALVE

The temperature and pressure relief valve (Fig. 5-2) is designed to open if the temperature of the
water within the heater reaches 210°F, or if the water pressure in the heater reaches 150 pounds.
park trailer water systems are closed systems and during the water heating cycle the pressure
build-up in the water system will reach 150 pounds. When this pressure is reached, the pressure
relief valve will open and water will drip from the valve. This dripping will continue until the
pressure is reduced to below 150 pounds, and the valve closes. This condition is normal and does
not indicate a defective relief valve.
I
WARNING: Do not place a valve between the relief valve and the tank. Do not plug
the relief valve under any circumstances.

THERMOSTAT AND MANUAL RESET

Models SW6D, SW6DE, SW6DM, SW6DEM: These water heaters are equipped with a high
temperature limit as a cut-off device. Temperature above 180°F will cause manual reset button to
trip, shutting down the main burner. (Fig. 5-3) To activate the burner, the water temperature must be
below 110°F, push the reset button to re-activate the burner.
Models SW6DE and SW6DEM: These water heaters are equipped with a high temperature limit as
a cut-off device. Temperature above 180°F will cause manual reset button to trip shutting down the
electric element. (Fig. 5-4) To activate the element, the water temperature must be below 110°F,
push the reset button to re-activate the element.
12-VOLT DC T-STAT
52
RESET
BUTTON
HI-LIMIT
Fig. 5-3
RESET
BUTTON
120-VOLT AC T-STAT
HI-LIMIT
Fig. 5-4
Cove Owner's Manual