30-amp Service

On a 30-amp system, up to 5 circuits are permitted to distribute power through the park trailer. All
breakers are sized according to power to be consumed.
I
WARNING: Do not replace breakers or fuses with any that are rated at a higher
amperage. Over fusing may cause a fire by over heating the wire.
Below is a generic drawing with circuit breaker alignment. Your park trailer may not be exactly the
same as shown depending on model, floor plan, and options.
Fig. 4-26
1
2
3
4 & 5
6
36
1
2
3
4
5
6
=
30-amp main, incoming power to coach
=
20-amp circuit to air conditioning
=
15-amp microwave oven
=
15-amp to general purpose circuits
=
15-amp service for optional water heater
Refer to 12-volt
DC System
for this layout
Cove Owner's Manual