2 .1 .2 System configuration and connection examples
The system configuration and connection examples are as follows.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
HINT
• The AeroDR SYSTEM and AeroDR SYSTEM 2 can be used together.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
 Basic configuration example
Number
Name
(1)
AeroDR Detector
(2)
AeroDR Interface Unit
(3)
AeroDR Interface Unit2
(4)
Hub
AeroDR Generator Interface
(5)
Unit
AeroDR Generator Interface
(6)
Unit2
(7)
AeroDR Battery Charger
AeroDR Battery Charger2 Charges the AeroDR Detector. It also has the registration function for the AeroDR Detector.
(8)
(9)
AeroDR Access Point
(10)
Access Point
(11)
AeroDR I/F Cable
(12)
AeroDR UF Cable
Image processing
(13)
controller
(14)
AeroDR XG Cable
(15)
AeroDR Collimator Cable
• There are 6 types of AeroDR Detectors: AeroDR 1417HQ, AeroDR 1417S, AeroDR
1717HQ, AeroDR 1012HQ, AeroDR 2 1417HQ and AeroDR 2 1417S.
• AeroDR Detector is of B-type Applied Parts.
• Supplies power to the AeroDR Generator Interface Unit, AeroDR Generator Interface
Unit2, and access point.
• Supplies power to and charges the AeroDR Detector when an AeroDR I/F Cable or
AeroDR UF Cable is used.
• It has a built-in hub function.
• 2 AeroDR Detectors can be connected via wired connection.
• The expansion AeroDR Interface Unit is required for connecting the third to seventh
AeroDR Detectors via wired connection.
• Supplies power to the access point.
• Supplies power to and charges the AeroDR Detector when an AeroDR I/F Cable or AeroDR
UF Cable is used.
• It has a built-in hub function.
• 2 AeroDR Detectors can be connected via wired connection.
• The expansion AeroDR Interface Unit is required for connecting the third to seventh AeroDR
Detectors via wired connection.
• Relays signals between the X-ray device, the AeroDR Detector, and the image processing
controller.
• Used to connect the AeroDR Generator Interface Unit2 or access point.
• General-purpose product.
• Product conforming to IEC 60950 (CLASS I) or equivalent standards.
Relays signals between the X-ray device, the AeroDR Detector, and the image processing
controller.
Relays signals between the X-ray device, the AeroDR Detector, and the image processing
controller.
Charges the AeroDR Detector. It also has the registration function for the AeroDR Detector.
IMPORTANT
• The AeroDR 1012HQ cannot be charged and registered using the AeroDR Battery
Charger.
• The AeroDR 2 1417S cannot be charged using the AeroDR Battery Charger.
Used for wireless connection with the AeroDR Detector.
• Used for wireless connection with the AeroDR Detector.
• General-purpose product.
• The AeroDR Access Point 2 is included.
Used for wired connection with the AeroDR Detector. Also used for charging and registering
the AeroDR Detector.
Registers the orientation when the AeroDR Detector is used for exposure in the wall stand/
table position.
• Controls the reception, management, and output of image data.
• Up to 7 AeroDR Detectors can be registered.
Performs signal relay between the X-ray device and the AeroDR Interface Unit2, AeroDR
Generator Interface Unit and AeroDR Generator Interface Unit2.
Performs exposure field signal relay between the X-ray device and the AeroDR Interface
Unit2 or AeroDR Generator Interface Unit.
29