10.12 N: Special Adjustment; N1: Hunting Prevention - YASKAWA GA700 Technical Manual

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

10.12 n: Special Adjustment

n1: Hunting Prevention

No.
Name
(Hex.)
n1-01
Hunting Prevention
Selection
(0580)
n1-02
Hunting Prevention
Gain Setting
(0581)
n1-03
Hunting Prevention
Time Constant
(0582)
n1-05
HuntingPrevention
Gain whileinRev
(0530)
n1-08
Leak cur antivib
(1105)
n1-13
DC Bus
Stabilization
(1B59)
Control
n1-14
DC Bus
Stabilization Time With a setting of n1-13 = 1 [DC Bus Stabilization Control =
(1B5A)
n1-15
Voltage Calibration
Select
(0BF8)
n1-16
High carry Hunt
Prev Gain
(0BFB)
n1-17
Hunt Prev Time
(0BFC)
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Enables or disables the hunting prevention function.
0 : Disabled
1 : Enabled
2 : Enable (High carry)
V/f
CL-V/f
OLV
CLV
AOLV
Adjusts the behavior of the hunting prevention function. Normally
there is no need to configure this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Adjusts the responsiveness (primary delay time constant) of the
hunting prevention function. Normally there is no need to configure
this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Adjusts the behavior of the hunting prevention function. Used to
adjust Reverse run. Normally there is no need to configure this
setting.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the method of suppressing motor vibration caused by
leakage current. Normally there is no need to configure this setting.
0 : Method1
1 : Method2
V/f
CL-V/f
OLV
CLV
AOLV
Enables or disables the oscillation suppression function for the DC
bus voltage.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Enabled], adjustments that address a lack of oscillation suppression
capability with respect to the DC bus voltage can be made.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the calibration method to be used for the suppression of
torque/current ripple.
0 : Calibration Invalid
1 : Calibrate only 1 time
2 : Calibrate every time
V/f
CL-V/f
OLV
CLV
AOLV
Adjusts the behavior of the hunting prevention function. This is
most effective when a high carrier frequency has been set. Normally
there is no need to configure this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Adjusts the responsiveness of the hunting prevention function.
Normally there is no need to configure this setting.
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM

10.12 n: Special Adjustment

Default
Ref.
(Range)
1
874
(0 - 2)
1.00
874
(0.00 - 2.50)
Determined by o2-
874
04
(0 - 500 ms)
0.00
874
(0.00 - 2.50)
0
875
(0, 1)
0
875
(0, 1)
100.0 ms
875
(50.0 - 500.0 ms)
1
875
(0 - 2)
0.50
876
(0.00 - 2.50)
500 ms
876
(0 - 1000 ms)
10
477

Advertisement

Table of Contents
loading

Table of Contents