B7: Droop Control; B8: Energy Saving - YASKAWA GA700 Technical Manual

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

b7: Droop Control

No.
Name
(Hex.)
b7-01
Droop Control
Gain
(01CA)
RUN
b7-02
Droop Control
Delay Time
(01CB)
RUN
b7-03
Droop Control
Limit Selection
(017E)

b8: Energy Saving

No.
Name
(Hex.)
b8-01
Energy Saving
Control Selection
(01CC)
b8-02
Energy Saving
Gain
(01CD)
RUN
b8-03
Energy Saving
Filter Time
(01CE)
RUN
b8-04
Energy Saving
Coefficient Value
(01CF)
b8-05
Power Detection
Filter Time
(01D0)
b8-06
Search Operation
Voltage Limit
(01D1)
b8-16
PM E-Save
Coefficient Ki
(01F8)
b8-17
PM E-Save
Coefficient Kt
(01F9)
b8-18
E-Save d-axis
Current FilterTime Configures the d-axis current reference filter time constant.
(01FA)
b8-19
E-Save Search
Injection Freq
(0B40)
b8-20
PM E-Save Search
Width
(0B41)
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the amount of deceleration when the torque reference is at
100% as a percentage of Maximum Output Frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Adjusts the responsiveness of Droop control. Lower this setting
when drive response is slow. Raise this setting when hunting or
oscillation occur.
V/f
CL-V/f
OLV
CLV
AOLV
Enables or disables the limit when using Droop control.
0 : Disabled
1 : Enabled
Description
V/f
CL-V/f
OLV
CLV
AOLV
Enables or disables Energy-saving control.
0 : Disabled
1 : Enabled
2 : Search Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Configures the gain for energy-saving control.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the responsiveness for energy-saving control.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the energy-saving coefficient. The energy-saving
coefficient is used to maintain maximum motor efficiency. The
default setting is the Yaskawa motor value.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the time constant used by the drive to measure output
power.
V/f
CL-V/f
OLV
CLV
AOLV
On the basis that the motor rated voltage is the 100% value, this
parameter configures the limit value of the voltage range defined for
Search Operations as a percentage.
V/f
CL-V/f
OLV
CLV
AOLV
This coefficient maintains torque linearity. Enter the Ki value
written on the motor nameplate. Normally there is no need to
change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
This coefficient maintains torque linearity. Enter the Kt value
written on the motor nameplate. Normally there is no need to
change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Configures the energy-saving control search operation frequency.
Normally there is no need to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Configures the amplitude of energy-saving control search
operations.
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
10.5 b: Application
Default
Ref.
(Range)
0.0%
636
(0.0 - 100.0%)
0.05 s
636
(0.03 - 2.00 s)
1
636
(0, 1)
Default
Ref.
(Range)
0
637
(Determined by
A1-02)
Determined by A1-
637
02
(0.0 - 10.0)
Determined by A1-
637
02, C6-01, and o2-
04
(0.00 - 10.00 s)
Determined by C6-
637
01, E2-11, and o2-
04.
(0.00 - 655.00)
20 ms
638
(0 - 2000 ms)
0%
638
(0 - 100%)
1.00
638
(0.00 - 3.00)
1.00
638
(0.00 - 3.00)
0.100 s
639
(0.000 - 5.000 s)
Determined by A1-
639
02
(20 - 300 Hz)
1.0 degrees
639
(0.1 to 5.0 degrees)
409
10