Installation Features

Power wiring can be routed through the top or bottom of each UPS cabinet.
External sensing and monitoring control wire must be installed in accordance with
Class 2 wiring methods. Bottom entry is provided for Class 2 wiring.

Options and Accessories

Contact your sales representative for information about any of these available
options:

Battery

You can enhance the protection provided by your UPS with one or more backup
battery supplies equipped with sealed lead-acid, maintenance-free batteries in a
matching cabinet. Each battery cabinet contains individual modular battery trays
and a battery circuit breaker. Several battery capacities are available.
The UPS battery cabinets can be paralleled; you can increase your battery backup
time by adding battery cabinets to your UPS system. Your UPS system can
support up to four (4) battery cabinets.

External Battery Disconnect

An optional DC circuit breaker, enclosed in a wall-mounted box adjacent to the
UPS, provides a manual means of disconnecting a battery that is located remotely
from the UPS. This option is described further in Chapter 6, "Using Features and
Options."

Power Distribution Module

An optional output power distribution module (PDM) is available to distribute the
output power of the UPS to your critical load. The PDM cabinet has two panels,
each containing up to 42 poles for breaker switches you can assign with flexibility
to meet the needs of your facility. Each panel is controlled by one 225 amp feeder
breaker. The PDM is enclosed in a separate cabinet that matches the UPS.

Upgrade Capability

The UPS is available in various output power ratings in both 50 and 60 Hz models.
If your power requirements increase, you can upgrade your UPS system to provide
more output power with a minimum impact on your facility.

Remote Monitor Panel

An optional Remote Monitor Panel (RMP) contains backlit status indicators and a
local horn, allowing you to monitor the operational status and alarm condition of
the UPS from virtually any location within your facility. You can install multiple
RMPs at remote locations to increase your monitoring capabilities. This option is
described further in Chapter 6, "Using Features and Options."

Relay Interface Module

An optional Relay Interface Module (RIM) uses relay contact closures to indicate
the operating status and alarm condition of the UPS system. The module uses a
serial interface line and may support up to eight critical loads. This option is
described further in Chapter 6, "Using Features and Options."
Input Isolation Transformer
Optional 480/480, 208/480, or 600/480 VAC input isolation transformers provide an
isolated input to the rectifier for applications that require a DC link that is not
ground referenced or for applications requiring an input of 208 or 600 VAC. The
transformers are contained in separate cabinets.
6
(available for North American voltages only)
Powerware 9315 (200 kVA ---300 kVA) Operation
164201036 Rev. D 041500