34 Site planning
All network components must support forwarding of IP multicast
packages. The DAP Configurator proposes a default multicast IP address
(239.192.49.49). This is a multicast address in the private multicast IP
address range that can be used in private IP networks. If you are not sure
you can access this address, contact the local IT manager.
ATTENTION
You must disable IGMP Snooping and Spanning Tree Protocol on switch ports
where SIP DECT equipment is connected.
DAP power configuration
DAPs are powered using one of the following methods.
Both phantom power and power over spare wires are provisioned on the
same DAP to provide system redundancy. The power provision providing
the highest voltage is active. If one of the power inputs fail, the other takes
over without service interruption.
Initial critical points on the floor plan to identify
A critical point is a place that can be difficult for the radio signal to reach,
such as a corner of a room, lifts, and stairwells. Initial critical points are
shown in
Figure 7 "Critical points" (page 35)
Copyright © 2008-2009 Nortel Networks
.
Locally using an RJ11 connector. The AC voltage must be 40V (+ or -
10%). Use an AC adaptor that provides at least 10 Watts. See
"Part numbers" (page 34)
Table 1
Part numbers
NTCW28AAE5
NTCW28BAE5
NTCW28CAE5
Through Power over Ethernet (PoE) as defined by IEEE802.3af
specifications. The DAPs support both phantom power and power over
spare wires. The following specifications are applicable to PoE power.
Minimum 36 Volts and maximum 60 Volts of voltage at the DAP
Standard RJ45 connector, using the spare wires pins (wires)
Maximum cable length of 100 meters
Figure 7 "Critical points" (page 35)
stairwell
second floor plan
Nortel Communication Server 1000
SIP DECT Fundamentals
NN43120-123 01.07
6 January 2009
for part numbers of available AC adaptors.
N0162030
DAP AC/AC adaptor Eur
N0162032
DAP AC/AC adaptor UK
N0162033
DAP AC/AC adaptor ANZ
as P1, P2, P3, and P4.