Sirens And Communicator In Accordance With En50131 Grade 3 - Bosch ICP-MAP5000-2 Installation Manual

Map 5000 series main panel intrusion alarm system
Hide thumbs Also See for ICP-MAP5000-2:
Table of Contents

Advertisement

MAP 5000
Reportable external tamper
alarm
Reportable panel summary
trouble
Reportable panel summary
armed
Reportable external fire alarm
Anti-mask intrusion trouble
External tamper alarm disarmed Tamper alarm from disarmed area with simultaneous
Transmission path fault
Ethernet path layer1 fault
Wireless path layer1 fault
IPC reporting failure
4.6.2

Sirens and communicator in accordance with EN50131 grade 3

Notice!
Sirens must be in operation for at least 90 seconds and a maximum of 15 minutes, unless
local or national requirements demand a shorter duration.
The following variants are possible:
Variant A (ICP-MAP0007 DE module and ICP-COM-IF required)
Variant B (ICP-COM-IF required)
Variant C (ICP-COM-IF required)
Bosch Sicherheitssysteme GmbH
Two supervised sirens
Connections 10 / 11 and 12 / 13 on the ICP-MAP0007 DE module)
One communicator (class 4)
Connections R1 – R7 on ICP-COM-IF
One self-powered siren
Outputs 10 / 11 or 13 / 14 on ICP-MAP5000 main panel
One communicator class 4
Outputs R1 – R7 on ICP-COM-IF
One communicator class 4 (main communicator)
Outputs R1 – R7 on ICP-COM-IF
One communicator class 3 (additional communicator)
Outputs R1 – R7 on ICP-COM-IF or other outputs on panel
Reporting of external tamper alarm event, possibly also
delayed if present/absent option is used
Reporting of panel summary trouble event, possibly also
delayed if present/absent option is used
Reporting of panel summary armed
Reporting of duress alarm event, possibly also delayed if
present/absent option is used
Covering of a motion detector
reporting via the communicator
In the event of communication failure between
communicator and receiver
In the event of failure of connection to network connector
In the event of failure of connection to network
field strength insufficient
registration not possible
GPRS service not available
no connection to the DE module
No acknowledgment received from the receiver within 240
sec.
Installation manual
Initial set-up and programming | en
2016.06 | 17 | F.01U.168.332
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icp-map5000-com

Table of Contents