en | Maintenance and service
P
LED status
Off
Fast blinking
Slow blinking
Permanently lit
Restoring the initial state of the panel
1.
2.
Failsafe mode
Forcing failsafe mode
Programming and panel firmware are deleted and RPS passcode is reset to default settings
when executing this option.
1.
2.
3.
4.
5.
6.
7.
Forcing extended failsafe mode
Programming, panel firmware and history are deleted and network settings are reset (DHCP,
0.0.0.0) when executing this option.
4
2016.06 | 17 | F.01U.168.332
The initialization phase, indicated by a blinking LED, starts.
The LEDs on the main panel and all other installed modules start indicating and the
system is ready for operation again.
Put the panel in Failsafe mode (see below).
Update the firmware.
Open the tamper switch.
De-energize the main panel (e.g. disconnect the small white connector at the rear of the
panel).
Press and hold the installer button.
Connect voltage (e.g. plug in small white connector again).
Release the installer button after 30 seconds.
Wait until operating LED is permanently lit (can take several minutes).
Transfer panel firmware "MAP_Update.Cumulative ...tar.bz2" again using RPS.
Carry out steps 1 – 6 of the above, then carry out steps 2 – 7.
Description
No function
Connection setup
Data exchange
Operating state