COMPONENT ACCESS
Removing the Display Board & 2-Way Valve
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
Remove Display PCB
1. First, perform preparation procedure on page 4-8, "Before
Disassembling the Coffee System" prior to performing the
following steps.
2. Next, perform the procedures to "Removing the Fan
Panel" on page 4-9.
3. Then, perform the procedures to "Removing the Back
Panel" on page 4-10.
4-20
Jenn-Air Built-in Coffee System
n
Figure 1
4. Remove 14 screws, seven (7) from each side (see Figures 2
and 3).
Figure 2
Figure 3