WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
1. Remove back panel (page 4-10) to access main power
board (see Figure 1).
2. Disconnect all harnesses. If necessary, label terminals and
connectors for ease of reinstallation.
3. To remove main board, remove the five (5) screws
securing PCB to chassis (see Figure 2).
Removing the Main Power Board
Figure 1
COMPONENT ACCESS
Figure 2
Jenn-Air Built-in Coffee System
4-11