The except keyword displays text that does not match the specified text. The following example shows this command used in
combination with the show system brief command.
Example of the except Keyword
Dell#show system brief | except 1
Stack MAC
Reload-Type
The find keyword displays the output of the show command beginning from the first occurrence of specified text. The following example
shows this command used in combination with the show system brief command.
Example of the find Keyword
Dell#show system brief | find 0
Stack MAC
Reload-Type
--
Stack Info
--
Unit
UnitType
------------------------------------------------------------------------------------
1
Management
2
Member
3
Member
4
Member
5
Member
6
Member
--
Power Supplies
Unit
Bay
Status
---------------------------------------------------------------------------
1
1
down
1
2
absent
--
Fan
Status
--
Unit Bay
TrayStatus
------------------------------------------------------------------------------------
1
1
up
1
2
up
1
3
up
Speed in RPM
The display command displays additional configuration information.
The no-more command displays the output all at once rather than one screen at a time. This is similar to the terminal length
command except that the no-more option affects the output of the specified command only.
The save command copies the output to a file for future reference.
NOTE:
You can filter a single command output multiple times. The save option must be the last option entered. For example:
Dell# command | grep regular-expression | except regular-expression | grep other-regular-
expression | find regular-expression | save.

Multiple Users in Configuration Mode

Dell Networking OS notifies all users when there are multiple users logged in to CONFIGURATION mode.
A warning message indicates the username, type of connection (console or VTY), and in the case of a VTY connection, the IP address of
the terminal on which the connection was established. For example:
42
Configuration Fundamentals
: 4c:76:25:e5:49:40
: normal-reload [Next boot : normal-reload]
: 00:11:12:13:18:20
: normal-reload [Next boot : normal-reload]
Status
ReqTyp
online
S3048-ON
not present
not present
not present
not present
not present
--
Type
FanStatus
AC
up
absent
Fan0
Speed
up
9900
up
9900
up
9900
CurTyp
S3048-ON
FanSpeed(rpm)
8128
0
Version
Ports
9-8(0-28)
52