Dell S3048-ON Configuration Manual page 906

Hide thumbs Also See for S3048-ON:
Table of Contents

Advertisement

show running-config entity
12
Verify that VLT is running.
EXEC mode
show vlt brief or show vlt detail
13
Verify that the VLT LAG is running in both VLT peer units.
EXEC mode or EXEC Privilege mode
show interfaces interface
Example of Configuring VLT
In the following sample VLT configuration steps, VLT peer 1 is Dell-2, VLT peer 2 is Dell-4, and the ToR is S60-1.
NOTE:
If you use a third-party ToR unit, Dell Networking recommends using static LAGs with VLT peers to avoid potential
problems if you reboot the VLT peers.
Configure the VLT domain with the same ID in VLT peer 1 and VLT peer 2.
Dell-2(conf)#vlt domain 5
Dell-2(conf-vlt-domain)#
Dell-4(conf)#vlt domain 5
Dell-4(conf-vlt-domain)#
Configure the VLTi between VLT peer 1 and VLT peer 2.
1
You can configure the LACP/static LAG between the peer units (not shown).
2
Configure the peer-link port-channel in the VLT domains of each peer unit.
Dell-2(conf)#interface port-channel 1
Dell-2(conf-if-po-1)#channel-member GigabitEthernet 1/4-1/7
Dell-4(conf)#interface port-channel 1
Dell-4(conf-if-po-1)#channel-member GigabitEthernet 1/4-1/7
Configure the backup link between the VLT peer units.
1
Configure the peer 2 management ip/ interface ip for which connectivity is present in VLT peer 1.
2
Configure the peer 1 management ip/ interface ip for which connectivity is present in VLT peer 2.
Dell-2#show running-config vlt
!
vlt domain 5
peer-link port-channel 1
back-up destination 10.11.206.58
Dell-2# show interfaces managementethernet 1/1
Internet address is 10.11.206.43/16
Dell-4#show running-config vlt
!
vlt domain 5
peer-link port-channel 1
back-up destination 10.11.206.43
Dell-4#
Dell-4#show running-config interface managementethernet 1/1
ip address 10.11.206.58/16
no shutdown
Configure the VLT links between VLT peer 1 and VLT peer 2 to the Top of Rack unit. In the following example, port Gi 1/4 in VLT peer 1 is
connected to Gi 1/8 of ToR and port Gi 1/18 in VLT peer 2 is connected to Gi 1/30 of ToR.
1
Configure the static LAG/LACP between the ports connected from VLT peer 1 and VLT peer 2 to the Top of Rack unit.
906
Virtual Link Trunking (VLT)