Mib Support To Display The Available Memory Size On Flash; Viewing The Available Flash Memory Size - Dell S3048-ON Configuration Manual

Hide thumbs Also See for S3048-ON:
Table of Contents

Advertisement

average input-power start time. These statistics can also be obtained by using the CLI command:
lists the related MIB objects, OID and description for the same:
Table 75. MIB Objects to Display the Information for Power Monitoring
MIB Object
envMonSupplyCurrentPower
envMonSupplyAveragePower
envMonSupplyAvgStartTime
SNMP Walk Example Output
snmpwalk -v 2c -c public 10.16.131.156 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.5
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.5.11 = INTEGER: 48
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.5.12 = INTEGER: 40
snmpwalk -v 2c -c public 10.16.131.156 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.6
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.6.11 = INTEGER: 31
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.6.12 = INTEGER: 26
snmpwalk -v 2c -c public 10.16.131.156 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.7
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.7.11 = STRING: "04/25/2017-18:32"
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.7.12 = STRING: "04/25/2017-18:32"
MIB Support to Display the Available Memory Size on
Flash
Dell Networking provides more MIB objects to display the available memory size on flash memory. The following table lists the MIB object
that contains the available memory size on flash memory.
Table 76. MIB Objects for Displaying the Available Memory Size on Flash via SNMP
MIB Object
chStackUnitFlashUsageUtil
The chStackUnitUtilTable MIB table contains the chStackUnitFlashUsageUtil MIB object which contains the flash memory usage percent.
The chStackUnitUtilTable is located in f10SSerChassisMib MIB.

Viewing the Available Flash Memory Size

To view the available flash memory using SNMP, use the following command.
snmpget -v2c -c public 192.168.60.120 .1.3.6.1.4.1.6027.3.10.1.2.9.1.6.1
enterprises.6027.3.10.1.2.9.1.5.1 = Gauge32: 24
The output above displays that 24% of the flash memory is used.
780
Simple Network Management Protocol (SNMP)
OID
1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.5
1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.6
1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.7
OID
1.3.6.1.4.1.6027.3.10.1.2.9.1.6
show environment . The following table
Description
Displays per PSU input power (current
configuration).
Displays average input power.
Displays average input-power start time.
Description
Contains flash memory usage in percentage.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents