Dell S3048-ON Configuration Manual page 809

Hide thumbs Also See for S3048-ON:
Table of Contents

Advertisement

Example of a Syslog
In the above example, stack unit 1 is the master management unit, stack unit 2 is the standby unit. The cables are connected to each unit.
Configure the stack groups on the units in the following order:
Configure the first stack group on unit 1: stack-unit 1 stack-group 1
Configure the stack groups on unit 2: stack-unit 2 stack-group 0 and stack-unit 2 stack-group 1
Configure the stack groups on unit 3: stack-unit 3 stack-group 0 and stack-unit 3 stack-group 1
Configure the stack groups on unit 4: stack-unit 4 stack-group 1 and stack-unit 4 stack-group 1
Configure the final stack-group on unit 1 to complete the stack: stack-unit 1 stack-group 0
When the stack-group configuration is complete, the system prints a syslog for reload.
Dell#configure
Dell(conf)#stack-unit 4 stack-group 0
Dell(conf)#02:39:12: %STKUNIT4-M:CP %IFMGR-6-STACK_PORTS_ADDED: Ports Te 4/49 have been
configured as
stacking ports. Please save and reload for config to take effect
Dell(conf)#stack-unit 4 stack-group 1
Dell(conf)#02:39:15: %STKUNIT4-M:CP %IFMGR-6-STACK_PORTS_ADDED: Ports Fo 4/50 have been
configured as
stacking ports. Please save and reload for config to take effect
Dell(conf)#
Dell#02:39:18: %STKUNIT4-M:CP %SYS-5-CONFIG_I: Configured from console
Reload each unit in the stack. After the reload is complete, the four units come up as a stack with unit 1 as the management unit, unit 2 as
the standby unit, and the remaining units as stack-members. All units in the stack can be accessed from the management unit.
NOTE:
Before executing show commands, you must wait for 10 to 15 seconds for the download-agent process to start.
To view the stack unit information after the reload, use the show system brief command.
Dell#show system brief
Stack MAC : 00:01:e8:8c:53:32
Reload Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType
Status
-----------------------------------------------------------------------
1
Standby
online
2
Management
online
3
Member
online
4
Member
online
5
Member
not present
6
Member
not present
-- Power Supplies --
Unit
Bay
Status
-----------------------------------------------------------
1
1
up
1
2
absent
2
1
up
2
2
absent
3
1
up
3
2
absent
4
1
up
4
2
absent
-- Fan Status --
Unit Bay
TrayStatus
-----------------------------------------
1
1
up
1
2
up
1
3
up
2
1
up
ReqTyp
CurTyp
S3048-ON
S3048-ON
S3048-ON
S3048-ON
S3048-ON
S3048-ON
S3048-ON
S3048-ON
Type
FanStatus
AC
up
absent
AC
up
absent
AC
up
absent
AC
up
absent
Fan0
Speed
up
7200
up
7200
up
7200
up
7200
Version
9.8(0.0P2)
9.8(0.0P2)
9.8(0.0P2)
9.8(0.0P2)
FanSpeed(rpm)
8000
0
8160
0
8000
0
8160
0
Ports
52
52
52
52
Stacking
809

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents