The trouble shooting information table below gives details on probable causes and
remedies should difficulties be encountered whilst the shower is in operation.
Warning! There are no user serviceable components beneath the cover of the
appliance. Only a competent tradesperson should remove the front cover!
Symptom
S h o w e r i s t o o
hot during the
summer.
S h o w e r i s t o o
hot.
T u r n i n g
t h e
t e m p e r a t u r e
control does not
affect the water
temperature.
Water continues to
flow when double
p o l e s w i t c h i s
turned off.
No water or very
low flow rate.

FAULT DIAGNOSIS

Heater
Setting
Power
Low/
Light
Med/
High
ON
High
ON
Med/
High
ON
Med/
High
OFF
Any
OFF
Any
ON
ON
Any
OFF
Any
Any
Probable Cause
I n c o m i n g w a t e r i s
warmer in the summer,
so the shower heater
setting is too high.
Handset blocked.
Handset blocked.
T h e d i a p h r a g m i s
damaged.
The power is off at the
double pole switch.
The incoming water
supply stop valves, or
the appliance isolating
valve, is closed.
Handset blocked.
The fuse is blown or the
MCB/RCD has been
tripped, indicating a
possible electrical fault.
22
Possible Remedy
Turn heater control to
m e d i u m a n d a d j u s t
temperature control until
the desired temperature
is achieved.
Remove and clean.
Remove and clean. If
fault persists, contact
the shower installer.
Contact shower installer
to replace the flow valve
assembly.
Switch on the power at
the double pole switch.
Open the stop/isolating
valve fully.
Remove and clean. For
sprayplate cleaning,
refer to the handset
manual.
Renew the fuse or reset
the MCB/RCD. If the
fault persists, contact
the shower installer.