Specifications - Mira Play 8.5 kW Installation & User Manual

Electric shower
Table of Contents

Advertisement

Mira Response Adjustable Shower Fittings
2 x Slide
Bar End Caps
2 x Wall Plugs
1 x Slide Bar
1 x 1.25 m
Flexible Hose
2 x Slide Bar
End Supports
1. Plumbing
1.1. Minimum maintained inlet pressure:
8.5 kW, 9.5 kW = 70 kPa (0.7 bar) 10.8 kW = 100 kPa (1.0 bar)
1.2. Maximum static inlet pressure of 1000 kPa (10 bar).
1.3. Minimum static inlet pressure of 50 kPa (0.5 bar) to keep the inlet valve
closed.
2. Electrical
2.1. The Mira Play 8.5 kW and 9.5 kW requires a 40 Amp fuse.
2.2. The Mira Play 10.8 kW requires a 45 Amp fuse.
2.3. The terminal block will accept cable sizes up to 16 mm
2.4. The Mira Play is suitable for installation in zone 1 and is rated IP X4.
3. Standards and Approvals
3.1. The Mira Play complies with all relevant directives for CE marking.

SPECIFICATIONS

7
1 x Handset
2 x Hose Seals
1 x Clamp
Bracket Assembly
1 x Soap Dish
1 x Hose Retaining Ring
2 x Fixing Screws
.
2