Mira Play 8.5 kW Installation & User Manual page 25

Electric shower
Table of Contents

Advertisement

Symptom
Water leaks from
the bottom of the
c a s e n e a r t h e
outlet. There is
no flow from the
outlet.
The water cannot
be turned off.
Heater
Setting
Power
Low/
Light
Med/
High
ON
Any
OFF
Any
OFF
Any
OFF
Any
Probable Cause
The pressure relief valve
in the heater tank has
been triggered (this
works to reduce the
damage to the appliance
if the outlet is blocked or
the unit is frozen.
When the relief valve
operates, a small rubber
ball is ejected.
T h e P i l o t Va l v e i s
faulty.
T h e d i a p h r a g m i s
damaged.
The supply pressure
is below the minimum
requirement.
25
Possible Remedy
Resolve the blocked
outlet, and replace the
tank assembly.
Replace.
Replace the flow Valve
assembly.
Contact local water
company.
Check the static water
pressure. Note! The
static pressure may
fall below minimum
requirement when other
appliances are drawing
water. For example, a
washing machine or
garden hose.