Read the section "Important Safety Information" first.

Plumbing Checklist

1.
Minimum maintained inlet pressure 8.5 kW and 9.5 kW = 70 kPa (0.7 bar).
Minimum maintained inlet pressure 10.8 kW = 100 kPa (1.0 bar).
Maximum static inlet pressure = 1000 kPa (10 bar).
2.
Water treatment device (if required).
3.
Free flowing isolating valve.
4.
Positioned over water catchment area.
5.
Fitted to finished wall surface.
6.
No sharp hose kinks.
7.
Fittings positioned with greater than 25 mm
gap or outlet double checkvalve fitted.
8.
Supply pipework flushed clear.
9.
Watertight inlet connection and fittings.
10. Cover secured correctly.
Minimum
200 mm from
ceiling.
Fixed to finished
wall surface.
Isolating Valve
Avoid sharp kinks

INSTALLER INSTRUCTIONS

25 mm Min
Bath
8
Convenient height
for all the family.
Hose Retaining Ring
Shower Tray